Geert De Pecker wrote: >I came to the .hal section below looking around on the net and >testing, but, while this seems to work from time to time, basically, >I'm not using the index signal which I would need for eg threading. > >Especially the line > >net spindle-phase-A <= parport.0.pin-11-in => encoder.0.phase-A >encoder.0.phase-Z > >Makes me wonder. This would send 50 indexes per turn. I guess one should >have a single Z index per turn to act as reference point when threading. > > Yep.
You described a physical setup with two pins connected (10 and 11), but you only connected one of them to the encoder (in two places). You need to connect phase-A to pin 11 and phase-Z to pin 10. - Steve ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users