2012/12/28 andy pugh <bodge...@gmail.com>:
> On 28 December 2012 10:04, Viesturs Lācis <viesturs.la...@gmail.com> wrote:
>
>> Here is a trace from halscope. I tried to check the consistency of
>> hall signals. They certainly do not seem like 60 degree hall pattern.
>
> Those don't look quite right, agreed.
>
> But, if they commutate the motors adequately, why not just use them?
> (ie, just stay in "h" mode all the time?)

Using them for initial commutation would be ok, but using them
permanently does not seem like a good idea, because that signal is not
differential and that is plasma table, so I expect some noise in the
signals, when plasma torch will be on. Signal cables are shielded and
shield is connected only on control box end to a separate ground wire,
machine frame also is grounded.

-- 
Viesturs