On 5/11/2015 11:02 AM, Peter C. Wallace wrote: > Non linear resolver output points to an overloaded input For a 7I49, I > would check that the maximum resolver output voltage is less than 1V > RMS (you need to rotate the shaft to find the peak on one or measure > both sine and cosine and calculate the peak as sqrt(Sine^2+Cosine^2)
I would do this with machine off, an measure at the individual leads coming off of the resolver correct? -- Thanks Rick Lair Superior Roll & Turning LLC 399 East Center Street Petersburg MI, 49270 PH: 734-279-1831 FAX: 734-279-1166 www.superiorroll.com ------------------------------------------------------------------------------ One dashboard for servers and applications across Physical-Virtual-Cloud Widest out-of-the-box monitoring support with 50+ applications Performance metrics, stats and reports that give you Actionable Insights Deep dive visibility with transaction tracing using APM Insight. http://ad.doubleclick.net/ddm/clk/290420510;117567292;y _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users