> Hi Sven. > It is a small machine but in any case I suggest to you to use a plc in stead > on LCNC. > I mean it is possibile to do it even with LCNC but will be much difficult. > I did many injection molding machine retrofit (the electric and Electronic > and software part) and a plc+hmi is the much confortable solution. > Realtime is needed as per machine cycle control (you have to be deterministic > for a precise and reliable control). > A 10ms task can be acceptable. > I personally made a hw and sw package with Schneider Electric plc M258 and > hmi Magelis GTO 10"" touch screen plus a software Application that I > personally developed. > But if you have time to spend and less money you cam try LCNC + MODBUS IO . > ;-)
I would say HMIs are quite exensive comparted to slightly outdated PC, what do you say about that? ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users