Hi Andy,

I fixed the typos.

Linux ports 0 and 1 did not work. 0x378 seemed to load (it did not give
error message). I still cannot make the motor turn if I set Parport Base
Address to 0x378 in Stepconf Wizard.


halcmd: loadrt hal_parport cfg="0"
Error: could not insert module
/usr/realtime-3.4-9-rtai-686-pae/modules/linuxcnc/hal_parport.ko: No such
device
<stdin>:3: exit value: 1
<stdin>:3: insmod for hal_parport failed, returned -1
See the output of 'dmesg' for more information.

halcmd: loadrt hal_parport cfg="1"
Error: could not insert module
/usr/realtime-3.4-9-rtai-686-pae/modules/linuxcnc/hal_parport.ko: No such
device
<stdin>:4: exit value: 1
<stdin>:4: insmod for hal_parport failed, returned -1
See the output of 'dmesg' for more information.

halcmd: loadrt hal_parport cfg="0x378"

bill@CNC:~$ dmesg
[  344.629510] config string '0'
[  344.630112] PARPORT: ERROR: linux parport 0 not found
[  350.869180] config string '1'
[  350.869752] PARPORT: ERROR: linux parport 1 not found
[  376.501674] config string '0x378'
[  473.293668] RTAI[math]: unloaded.
[  473.294579] SCHED releases registered named ALIEN PEDV$D
[  473.300000] RTAI[malloc]: unloaded.
[  473.396940] RTAI[sched]: unloaded (forced hard/soft/hard transitions:
traps 0, syscalls 0).
[  473.397846] I-pipe: head domain RTAI unregistered.
[  473.397880] RTAI[hal]: unmounted.
------------------------------------------------------------------------------
_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to