On 11/8/19 5:37 AM, Todd Zuercher wrote:
I could see worn pulleys on toothed drive belts, and/or over tightened drive 
belts giving results with delayed backlash take-up like that.

I am using a Sherline CNC Lathe. There are no belts or pulleys associated with axis movement.

Todd Zuercher
P. Graham Dunn Inc.
630 Henry Street
Dalton, Ohio 44618
Phone:  (330)828-2105ext. 2031

-----Original Message-----
From: Thomas D. Dean <[email protected]>
Sent: Friday, November 08, 2019 12:30 AM
To: [email protected]
Subject: [Emc-users] Axes Names, Backlash and Overshoot

I have a Sherline CNC Lathe with the computer system from Sherline.  The disk 
drive failed.  I replaced the disk and installed LinuxCNC 2.7.14.
The install completed without error - great job.

I have a problem with backlash and overshoot.

The config file has a strange entry:
AXES = 3
COORDINATES = X Z

Should there be names for 3 axes?

I checked the motion with a Fowler digital dial indicator.

Backlash = 0.000
            Motion   Fowler
Start               +0.0001
           -0.0100    -0.0080 moved -0.0081
           -0.0100    -0.0175 moved -0.0095
           -0.0100    -0.0275 moved -0.0100
           -0.0100    -0.0375 moved -0.0100
           +0.0100    -0.0305 moved +0.0070
           +0.0100    -0.0210 moved +0.0095
           +0.0100    -0.0110 moved +0.0100
           +0.0100    +0.0010 moved +0.0100

Backlash = 0.0020
            Motion   Fowler
Start               +0.0100
           -0.0100    +0.0005 moved -0.0095
           -0.0100    -0.0075 moved -0.0080
           -0.0100    -0.0175 moved -0.0100
           +0.0100    -0.0055 moved +0.0120
           +0.0100    -0.0010 moved +0.0045
           +0.0100    -0.0110 moved +0.0100

Backlash = 0.0030
            Motion   Fowler
Start               +0.1245
           -0.0100    +0.1135 moved -0.0110
           -0.0100    +0.1065 moved -0.0070
           -0.0100    +0.0960 moved -0.0105
           -0.0100    +0.0860 moved -0.0100
           +0.0100    +0.0990 moved +0.0130
           +0.0100    +0.1060 moved +0.0070
           +0.0100    +0.1155 moved +0.0095
           +0.0100    +0.1255 moved +0.0100

Backlash = 0.0035
            Motion   Fowler
Start               +0.1260
           -0.0100    +0.1140 moved -0.0120
           -0.0100    +0.1075 moved -0.0065
           -0.0100    +0.0970 moved -0.0105
           -0.0100    +0.0875 moved -0.0095
           +0.0100    +0.1010 moved +0.0135
           +0.0100    +0.1080 moved +0.0070
           +0.0100    +0.1175 moved +0.0095
           +0.0100    +0.1270 moved +0.0095

I do not understand the relationship between the variables in the ini file.  
Except for the backlash, I have not changed anything from the distribution file.

How do I fix this?

Tom Dean


_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users


_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users


Tom Dean


_______________________________________________
Emc-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/emc-users

Reply via email to