At 08:52 AM 7/10/2008, Doug McCormack wrote:
>I saw a similar discussion on the Kenwood site last year.  The problem was
>traced to corrosion on the in-line fuse holder between the power supply and
>the rig.
>
>If there are any problems on this wire like a tired fuse, corroded fuse
>holder, under-sized wire, or bad soldering; the voltage in the rig will sag
>on voice peaks, even though the voltage may show rock steady coming out of
>the power supply.


And there was a similar issue with frequency stability on the SDR1K, 
where under load, the power supply sagged a bit, causing the 
temperature of the thermistor on the crystal to change a bit, etc.

Jim