Frank,

I can answer number 1 for you, here is my wakeup parm file from VMUTIL

WAKEUP   PARMS    Z1  F 80  Trunc=80 Size=98 Line=71 Col=1 Alt=5
 
0071 
0072 M-F      00:05:00 03/12/10 EXEC NJE$RJE 
0073 M-F      00:15:00 03/12/10 CP CHANGE RSCS RDR ALL NOHOLD 
0074 M-F      00:30:00 03/12/10 EXEC NEWBBH 
0075 ALL      00:45:00 03/12/10 EXEC UIERUN 
0076 M-F      02:00:00 03/12/10 CMS VMBACKUP SUBMIT BBHDAILY 
0077 SAT     02:00:00 03/06/10 CMS VMBACKUP SUBMIT BBHDAILY 
0078 SUN     03:00:00 03/07/10 CMS VMBACKUP SUBMIT BBHWEEK 
0079 *  N       03:00:00 03/01/10 CMS VMBACKUP SUBMIT BBHMONTH 
0080 *  N       02:00:00 11/01/09 CP SET TIMEZONE EST 
0081 SUN     02:00:00 11/01/09 CP SET TIMEZONE EDT 
0082 *  BEGIN OF  TEST 
0083 *        02:00:00 10/12/09 EXEC PERF 
0084 *  END   OF  TEST 
0085 *  BEGIN OF  DAY  SHIFT 
0086 M-F      07:00:00 03/12/10 EXEC NJE$RJE 
0087 M-F      07:15:00 03/12/10 CP CHANGE RSCS RDR ALL NOHOLD 
0088 ALL      08:00:00 03/12/10 EXEC WATCHON 
0089 SAT      08:01:00 03/06/10 CMS PRINT VMUTIL LOG 
0090 SAT      08:03:00 03/06/10 CMS ERASE VMUTIL LOG 
0091 M-F      12:00:00 03/11/10 EXEC NJE$RJE 

munson
201-418-7588





"Frank M. Ramaekers" <framaek...@ailife.com> 
Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
03/12/2010 10:59 AM
Please respond to
The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>


To
IBMVM@LISTSERV.UARK.EDU
cc

Subject
Daylight Saving Time w/ VSE






This is the first time (in quite some time) that I?ve had a Daylight 
Saving Time (Spring Forward).  Last year we did a Fall Backward by 
shutting the system down for one hour.
 
So, here are my questions:
 
1)         VM time has to be done manually?   Has anyone done this via 
VMUTIL (for example?
2)         Does anything need to be done to the z/VSEs (when springing 
forward)?
3)         Will z/VSE pick up the time change when it?s changed on VM?
4)         Are there special conditions for 2 and 3 above (specifically 
SET CLOCK/ZONE/ZONEDEF/ZONEBDY settings)
 

 Frank M. Ramaekers Jr.
 
Systems Programmer
MCP, MCP+I, MCSE & RHCE
American Income Life Insurance Co.
Phone: (254)761-6649
1200 Wooded Acres Dr.
Fax: (254)741-5777
Waco, Texas  76701
 
 
_____________________________________________________ This message 
contains information which is privileged and confidential and is solely 
for the use of the intended recipient. If you are not the intended 
recipient, be aware that any review, disclosure, copying, distribution, or 
use of the contents of this message is strictly prohibited. If you have 
received this in error, please destroy it immediately and notify us at 
privacy...@ailife.com. 

*************************** IMPORTANT
NOTE*****************************-- The opinions expressed in this
message and/or any attachments are those of the author and not
necessarily those of Brown Brothers Harriman & Co., its
subsidiaries and affiliates ("BBH"). There is no guarantee that
this message is either private or confidential, and it may have
been altered by unauthorized sources without your or our knowledge.
Nothing in the message is capable or intended to create any legally
binding obligations on either party and it is not intended to
provide legal advice. BBH accepts no responsibility for loss or
damage from its use, including damage from virus.
********************************************************************************

Reply via email to