Braidwood:

Ludlum 3030P

Max is 500k dpm

Cut the smear is more than 500k and record on survey 

 

Amanda L. Stenson

Exelon Corp - Braidwood NPS

RP Technical Specialist

(815)417-2712

   <http://inside.exeloncorp.com/orgs/home/default.htm> 

________________________________

From: [email protected] [mailto:[email protected]] On Behalf
Of Byrum, William F
Sent: Monday, August 27, 2012 7:46 AM
To: [email protected]
Subject: Powernet: Alpha Counting

 

Duke Energy request to following information:

 

 

What do you use to count smears for alpha/ beta activity?    Canberra
iSolo,  Ludlum 3030P, other?

 

Do you have a limit on the activity (dpm) that can be counted using a
smear counter?  

 

And if you have a limit on activity, what is the limit and how do you
count smears above the activity limit (beta) for alpha?

 

Bill Byrum, CHP,RSO

EnRad Laboratories

Duke Energy

[email protected] <mailto:[email protected]> 

Phone 980.875.5811

 




-----------------------------------------
**************************************************
This e-mail and any of its attachments may contain Exelon
Corporation proprietary information, which is privileged,
confidential, or subject to copyright belonging to the Exelon
Corporation family of Companies. 
This e-mail is intended solely for the use of the individual or
entity to which it is addressed.  If you are not the intended
recipient of this e-mail, you are hereby notified that any
dissemination, distribution, copying, or action taken in relation
to the contents of and attachments to this e-mail is strictly
prohibited and may be unlawful.  If you have received this e-mail
in error, please notify the sender immediately and permanently
delete the original and any copy of this e-mail and any printout.
Thank You.
**************************************************

<<image002.gif>>

<<image003.jpg>>

Reply via email to