Cook Plant uses a Ludlum 3030P or a Canberra S5E.
Contamination limit is 250,000 dpm.
Ideally, if higher contamination, we would get a lower activity smear. We 
have also cut the smear and taken a smear of a smear.

Joe Beer,  CHP
Staff Health Physicist
Cook Nuclear Plant, Mail Zone 9
One Cook Place
Bridgman, MI 49106
audinet: 280-2262
work: 269-465-5901 ext 2262
fax:    269-466-2661
cell:   269-313-7782
[email protected]



"Byrum, William F" <[email protected]> 
Sent by: [email protected]
08/27/2012 08:45 AM
Please respond to
[email protected]


To
"[email protected]" <[email protected]>
cc

Subject
Powernet: Alpha Counting







Duke Energy request to following information:
 
 
What do you use to count smears for alpha/ beta activity?    Canberra 
iSolo,  Ludlum 3030P, other?
 
Do you have a limit on the activity (dpm) that can be counted using a 
smear counter? 
 
And if you have a limit on activity, what is the limit and how do you 
count smears above the activity limit (beta) for alpha?
 
Bill Byrum, CHP,RSO
EnRad Laboratories
Duke Energy
[email protected]
Phone 980.875.5811
 



----------------------------------------------------------------
This e-mail message and all attachments transmitted with it from the
Nuclear Generation Group of American Electric Power are for the sole
use of the intended recipient(s) and may contain confidential and 
privileged information.  Any unauthorized review, use, disclosure or 
distribution is prohibited.  If you are not the intended recipient, please
contact the sender by reply e-mail and destroy all copies of the original 
message.

<<image/gif>>