GSAS/EXPGUI use on Mac and Linux

2010-03-12 Thread Brian H. Toby
Brian H. Toby, Ph.D.office: 630-252-5488 Senior Physicist/Section Head for Scientific Software Advanced Photon Source 9700 S. Cass Ave, Bldg. 401/B4192work cell: 630-327-8426 Argonne National Laboratory Argonne, IL 60439-4856

Re: CIF file conversion

2010-02-25 Thread Brian H. Toby
On Feb 25, 2010, at 6:31 AM, r.m.wil...@qmul.ac.uk wrote: A quick question: does anyone know of any programs that will convert CIF data into a GSAS readable EXP file format? Brian H. Toby, Ph.D.office

Re: diffraction patterns or spectra

2010-02-11 Thread Brian H. Toby
diffraction patterns are often referred to as diffraction spectra. But we all know that diffraction is not a spectroscopic technique. A spectrum refers to a wavelength-dispersive measurement, while CW diffraction is spatially resolved. Either diffraction pattern or diffractogram is the

Re: about background substraction

2009-05-19 Thread Brian H. Toby
to know. Brian Brian H. Toby, Ph.D.office: 630-252-5488 Senior Physicist/Materials Characterization Group Leader Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell: 630-327

Re: UVW

2009-03-19 Thread Brian H. Toby
). Brian H. Toby, Ph.D.office: 630-252-5488 Senior Physicist/Materials Characterization Group Leader Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell: 630-327-8426 Argonne National Laboratory secretary (Marija): 630-252-5453 Argonne, IL

Re: GSAS data formats

2009-03-15 Thread Brian H. Toby
Matthew Rowles CSIRO Minerals Box 312 Clayton South, Victoria AUSTRALIA 3169 Ph: +61 3 9545 8892 Fax: +61 3 9562 8919 (site) Email: matthew.row...@csiro.au Brian H. Toby, Ph.D.office

Re: Rietveld: U,V,W

2008-11-30 Thread Brian H. Toby
be interested to get those relationships into CMPR; I am not sure if the scaling is only between centidegrees**2 and degrees**2.) Brian Brian H. Toby, Ph.D.office: 630-252-5488 Materials

Re: GSAS bond angle reconstraints

2008-11-25 Thread Brian H. Toby
can use the dummy atom in the constraint. This should work, but I have not tried it. Brian Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced Photon Source

Re: unit cell size limitation in GSAS?

2008-11-12 Thread Brian H. Toby
*** Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell: 630-327-8426 Argonne National Laboratory

Re: confusion about some GSAS parameters

2008-08-07 Thread Brian H. Toby
On Aug 7, 2008, at 12:02 PM, [EMAIL PROTECTED] wrote: So, for the case of a brag brenteno diffractometer without any monochromator, will the value for POLA should be fixed to zero?? There are two GSAS polarization models (read the manual!), but my recollection is that for IPOLA=0,

Re: 1/Yo**2 weighting scheme in Rietveld refinement

2008-03-14 Thread Brian H. Toby
On Mar 14, 2008, at 5:41 AM, Franz Werner wrote: w=1/Yo**2 [weighting] is proposed (By using the new weighting scheme, the accuracy of positional parameters of the test sample was significantly improved relative to the weight function 1/Yo, which weights the medium and strong intensities

Re: Graphic superposition of crystal structures

2008-01-21 Thread Brian H. Toby
On Jan 17, 2008, at 4:04 PM, Franz Werner wrote: Does anyone know a free program capable of overlaying crystal structures? The DRAWxtl program has some capabilities for this -- see the frame command. http://home.att.net/~larry.finger/drawxtl/ Brian

Re: Crystallography/MS Word Question: 3 bar

2008-01-14 Thread Brian H. Toby
On Jan 14, 2008, at 4:36 AM, Holger Kohlmann wrote: try the font Arial Overlined, but make sure to install it on any computer you use. I once gave a talk with the title 1 bar, written in Arial Overlined. Of course, the computer in the lecture hall did not have that font, which turned the

Crystallography/MS Word Question: 3 bar

2008-01-11 Thread Brian H. Toby
I have heard that there are several ways to create a 3 with an over- bar symbol (as would be used for space group R -3 c, for example) in Micro$oft Word, but none are convenient. I know how to do this with the equation editor. Can anyone contribute any better choices? Brian

Re: question about PowPref, GSAS

2007-12-16 Thread Brian H. Toby
Choice of space group origin will affect the computation of intensities but not which reflections are included in the pattern, so that is not the problem. The fact that the 222 reflection shows up in reflist makes it seem likely to me that you do not have the space group input correctly.

Re: inclusion of organic template with GSAS

2007-12-11 Thread Brian H. Toby
is good enough or should I try the rigid unit option (which does not look trivial, any good link discussing this option?) Thanks for your help. Regards, Ramdas Pophale. Brian H. Toby, Ph.D.office

Re: GSAS on Windows Vista

2007-11-27 Thread Brian H. Toby
On Nov 27, 2007, at 7:48 AM, Davide Levy wrote: I am changing PC and I would like to know if there are problem to run GSAS-EXPGUI with Windows Vista. I have heard reports of problems with running the self-installer. This probably requires use of a sys admin account on Vista (and probably

Re: Difference Fourier Map/GSAS

2007-11-22 Thread Brian H. Toby
as permitted by UK legislation. Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell: 630-327

Re: Difference Fourier Map/GSAS

2007-11-22 Thread Brian H. Toby
On Nov 22, 2007, at 11:30 AM, Telepeni Irvin wrote: Thanks for your reply, that must be the explanation, but I am not quite sure of how to filter these sites from those of interest (since I dont know where they are)? I could just try all of them but I am sure that's not the ideal method.

Re: Kapton capillaries

2007-11-16 Thread Brian H. Toby
Could someone please suggest a source for purchasing kapton capillaries? A search on the internet drew a blank. Try polyimide rather than kapton. We have used MicroLumen as a vendor: http://www.microlumen.com/ Brian

Re: Instrumental parameter file

2007-09-27 Thread Brian H. Toby
, your group should be able to manage the cost of a single-seat license; cost compares favorably to the student-discounted price for many commonly used software packages. /soapbox Brian Brian H. Toby, Ph.D

Re: Is it possible in GSAS to control the value of certain parameters in a

2007-04-23 Thread Brian H. Toby
Re: Is it possible in GSAS to control the value of certain parameters in a... For example, Uiso0, 0F1, etc No. Nor would you want to do this. When Uiso or Occupancy refine to non-physical numbers (particularly with neutron data) there is a implicit message that your model is not fitting

[Fwd: [ccp4bb] Nature policy update regarding source code]

2007-03-24 Thread Brian H. Toby
Begin forwarded message: From what I have read on Nature Methods decision then if the journals of J. Applied Cryst and Acta Cryst were to go down the same path then 2000 plus users of TOPAS and TOPAS-Academic would be without a means of reading peer reviewed articles on the algorithms used

Re: Exporting GSAS powplot data

2007-03-15 Thread Brian H. Toby
Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell: 630-327-8426 Argonne National Laboratory secretary (Marija): 630-252-5453 Argonne, IL

Announcement: GSAS-II Workshop May 10-11, 2007

2007-03-14 Thread Brian H. Toby
. Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell: 630-327-8426 Argonne National Laboratory secretary (Marija): 630-252-5453 Argonne

Powder Diffraction In Q-Space: plotting CIFs

2007-02-22 Thread Brian H. Toby
to take pdCIF into the next decade. I think I have paid my dues. I will not make any (more?) enemies by suggesting suitable candidates. Brian Brian H. Toby, Ph.D.office: 630-252-5488 Materials

Re: Powder Diffraction In Q-Space

2007-02-21 Thread Brian H. Toby
WYSIWYG to XMGRACE or as a .csv file. Brian Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced Photon Source 9700 S. Cass Ave, Bldg. 433/D003 work cell

Re: scale factor

2006-12-12 Thread Brian H. Toby
, but I will never fix the scale factor, since that is completely arbitrary in almost all experiments. Brian Brian H. Toby, Ph.D.office: 630-252-5488 Materials Characterization Group Leader, Advanced

Re: GSAS: Linux install

2006-10-25 Thread Brian H. Toby
is the command line -is there a GUI front?I can not find the ./cshrc file either? Is that particular to Red Hat or am Imissing something?Is there an uptodate binary or rpm version at all and 64 bit?Kind regardsWilliam Bisson  Brian H

Re: Dummy histograms

2006-09-14 Thread Brian H. Toby
charity (number 227938)   Brian H. Toby, Ph.D.                            office: 630-252-5488Materials Characterization Group Leader, Advanced Photon Source9700 S. Cass Ave, Bldg. 433/D003             work cell: 630-327-8426

Re: GSAS ESD/STD conversion

2006-06-28 Thread Brian H. Toby
be surprised if FullProf does not have a way to input intensities with uncertainties rather than assuming intensities are counts.Brian  Brian H. Toby, Ph.D.                            office: 630-252-5488Materials Characterization

Re: Converting .RAW file to correct format in GSAS

2006-06-20 Thread Brian H. Toby
On Jun 20, 2006, at 10:37 AM, [EMAIL PROTECTED] wrote:I am trying to import a histogram which is in the .RAW format into GSAS. I am having problems converting this into the correct format for GSAS. The error says permission denied. How can I solve this problem and/or get a permission to convert

Re: CIFs for powder diffraction/Software testing

2005-03-02 Thread Brian H. Toby
Brian H. Toby wrote: At present, to my knowledge, there is exactly one program that can be used to read plot powder diffraction data from these CIFs: pdCIFplot This turns out to be wrong. CMPR can also do this (http://www.ncnr.nist.gov/xtal/software/cmpr/). My apologies to the author

Re: Rf values in GSAS

2005-02-03 Thread Brian H. Toby
Run program rfactor. You get the choice of computing on F**2 or F. Brian Does anyone know any way of extracting Rf values from a GSAS powder data refinement? I can't find any mention of it in the manual.

Re: Rigid body constraints on perovskite structured materials

2004-11-15 Thread Brian H. Toby
As per Brian Toby's advice on using strong restraints instead of rigid bodies. My advice was to use restraints (soft constraints) together with rigid bodies, although, restraints on both bond distances and angles can be an alternate strategy. Brian

Re: A question about stacking faults

2004-10-07 Thread Brian H. Toby
wrote: Are there anybody experienced in stacking faults? Please help me! Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8563 voice: 301-975-4297

Windows GSAS+EXPGUI *now* updated

2004-10-01 Thread Brian H. Toby
Friends, My previous e-mail stated that the combined GSAS/EXPGUI distribution had been updated for all four supported platforms. This was wrong. I just discovered that the updated Windows version did not get onto the webserver until a few minutes ago (my fault). My sincere apologies to all

Updates to GSAS+EXPGUI

2004-09-30 Thread Brian H. Toby
Friends, A new and updated combined release of GSAS EXPGUI is now available on all platforms (Windows http://www.ncnr.nist.gov/xtal/software/expgui/expgui_Win_readme.html, LINUX/SGI http://www.ncnr.nist.gov/xtal/software/expgui/expgui_Unix_readme.html, or Mac OS X

Re: Ca, Sr-chabazite

2004-09-21 Thread Brian H. Toby
Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8563 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847Gaithersburg, MD

Re: Conversion software available?

2004-08-26 Thread Brian H. Toby
(f' f) will not be computed correctly. Brian I am looking for software that can convert the x-ray diffraction data of one radiation source to the other. Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL

Re: Rietveld refinement and PDF refinement ?

2004-08-19 Thread Brian H. Toby
Alan, But if you refine the full data with the same model, can there really be any fundamental difference, if in one case you simply do a Fourier transform to real space ? in Rietveld refinement we throw away the non-Bragg peak data, where-as with PDF all scattering is included. It is

Re: PDF-4

2004-07-28 Thread Brian H. Toby
of the the new PDF-4 Database, is public, and if there is a database access tool for LINUX/UNIX systems? thank you in advance, Friedrich -- Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST

Re: EXPGUI updates?

2004-07-27 Thread Brian H. Toby
/ == -- Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8563 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847

Re: Next Endeavour version without Hofmann potential

2004-07-08 Thread Brian H. Toby
I have to agree with Vincent that I find aspects of CCDC's apparent actions troubling and warrant discussion even if all parties reach a happy agreement behind closed doors. If the CCDC claims partial ownership of everything derived from their database then how far does that go? Can they

CIF files input to GSAS

2004-05-18 Thread Brian H. Toby
. The Pennsylvania State University http://www.personal.psu.edu/mjg301/ == -- Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron

Re: Fixing parameters in GSAS

2004-04-22 Thread Brian H. Toby
Nope -- EXPGUI does not handle the Fix option (yet). Brian Peter Zavalij wrote: The easiest way is to use EXPGUI graphic user interface by Brian Toby. Peter Zavalij -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] Sent: Thursday, April 22, 2004 5:05 AM To: [EMAIL

no new EXPGUI yet

2004-04-22 Thread Brian H. Toby
Dr. K. Selvaraj wrote: Dear Brian Is there a latest version of EXPGUI ? Thanks I am trying to find some free time to track down a few EXPGUI bugs. Once they are caught, I'll put together a new release of EXPGUI combined with the latest version of GSAS for windows. After that, then Mac OSX,

Re: GSAS information (anisotropic microstrain)

2004-04-07 Thread Brian H. Toby
My advice on this question is that one should not use this approach. The Stephens formalism, coded in profile type 4, is better founded by theory. See the GSAS manual and reference to Peter Stephen's J. Appl. Cryst paper from a few years back. Brian Christophe Chabanier wrote: Hello

Re: GSAS information (anisotropic microstrain)

2004-04-07 Thread Brian H. Toby
- under certain circumstances and restrictions to the parameters - a physical meaning, e.g. concentration fluctuations can show up like this, and the type of anisotropy constitutes a special case of the Stephens model. Best regards Andreas Leineweber Brian H. Toby wrote: My advice

Note to software designers

2004-03-18 Thread Brian H. Toby
. Brian Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847

Re: RIET:STX:Latest IUCr Commission on Powder Diffraction Newsletteron-line

2001-09-04 Thread Brian H. Toby
7HX, London, UK Tel: (+44) 020 7631 6849 Fax: (+44) 020 7631 6803 E-mail: [EMAIL PROTECTED] WWW: http://www.ccp14.ac.uk -- Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST

latest GSAS version: for SGI and Linux

2001-06-29 Thread Brian H. Toby
Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847Gaithersburg, MD 20899

Re: new GSAS (EXPGUI)

2001-04-10 Thread Brian H. Toby
ux release. ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847Gaithersburg, MD 20899-8562

Neutron diffraction with boron

2001-03-28 Thread Brian H. Toby
reactor has been postponed until our scheduled upgrade in August. We plan to resume operations in about 2 weeks. Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron

Re: GSAS profile #4 FWHM

2001-03-22 Thread Brian H. Toby
-phase option in REFLIST prints a list of reflections and their FWHM. This may be a better way to solve your problem. Brian Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center

EXPGUI update

2001-03-08 Thread Brian H. Toby
to EXPGUI. Please write to me directly. Brian ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of

EXPGUI bug (was Win-GSAS question/problem)

2000-12-22 Thread Brian H. Toby
st. After I get some feedback on the impact of these changes, the "stable" EXPGUI version will be updated. Happy Hannuka, Christmas, Ramadan, Diwali, Kwanzaa or whatever, Brian ******** Brian H. Toby, Ph.D.Leade

more ranting on databases

2000-11-13 Thread Brian H. Toby
The question "who really possess the copyright" of such data mainly produced at academic research institutions has no clear answer. Not so. I am no expert on copyright laws, but I do believe one can obtain copyright protection on a collection of information, even if the contents are in the

Re: Natrite - Na2 CO3

2000-11-09 Thread Brian H. Toby
Uwe Kolitsch wrote: (by the way, the ICSD costs only 500 US dollars per year). A company such as USG would not be able to lease the ICSD at the $500 academic price. I no longer remember the for-profit price, but it is significantly more. However, these prices cover the cost of tabulating the

Re: Thermal Parameters and Occupancies

2000-10-06 Thread Brian H. Toby
il: [EMAIL PROTECTED] -- ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847Gaither

Re: SRMs 640c 660a

2000-09-29 Thread Brian H. Toby
with respect to impurities and with respect to processing, one would expect their lattice constants to differ, too. Brian Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center

Re: mixing parameter

2000-08-14 Thread Brian H. Toby
functions for CW data. How can I refine the mixing paramter eta in a pseudo-Voigt function with GSAS? - Holger Kohlmann -- Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center

Re: Powplot problems with NT

2000-08-08 Thread Brian H. Toby
Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847

Re: Lp correction in GSAS

2000-07-10 Thread Brian H. Toby
ts. Brian ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847Gaithersburg, MD

IUCr policy statement on STAR/CIF

2000-05-17 Thread Brian H. Toby
FT - DRAFT - DRAFT - DRAFT - DRAFT - DRAFT - DRAFT -- ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National

[Fwd: Announcing a new discussion list for developers of CIF software]

2000-05-09 Thread Brian H. Toby
The discussion list described below will be of interest to anyone wishing to develop software that reads or writes CIF files. (I sure hope there are at least a few people in the powder community who fit that description.) Brian Announcing a new discussion list for developers of CIF software.

Re: Kalpha2

2000-03-29 Thread Brian H. Toby
someone please elaborate? Thanks, Brian Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards

Re: Asymmetry

2000-03-07 Thread Brian H. Toby
asymmetry in low angle X-ray powder diffraction data? ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National

Re: New version of PC-GSAS

2000-03-03 Thread Brian H. Toby
Bob, Hurray! Are you including tcldump exptool in your distributions? If not, could you at least compile them as you do each platform? Let me know anything I can do to help. Brian

CMPR for Windows and UNIX

1999-12-21 Thread Brian H. Toby
Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847Gaithersburg, MD 20899-8562

Re: gsas in dos UNIX

1999-11-08 Thread Brian H. Toby
t screw up the file, if you convert a file that is already in the correct format. Brian ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 30

Re: Data Format

1999-11-08 Thread Brian H. Toby
Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of Standards Technology FAX: 301-921-9847

Re: RIET: Re: [sdpd] Re: Use of CIF as advocated by Lachlan

1999-11-08 Thread Brian H. Toby
implemented as a raw data format. Brian Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute

Re: Bond length and angle ESDs

1999-09-23 Thread Brian H. Toby
Is there a program which can take as input the atomic positions and lattice parameters and the associated errors and give as an output an estimation of the bond lengths, angles and associated errors? I think that doing this would give an overestimation of the errors (for example it neglects

Re: Help: find calculated peak intensities/areas in GSAS

1999-05-11 Thread Brian H. Toby
2 0 0 3 2 1121 4.68645 0.000E+00 2.574E+05 0.000E+00 6.972E+03 3 1 0 1 6 1021 2.40416 0.000E+00 7.497E+04 0.000E+00 3.426E+03 Could anybody kindly help me out here? Many thanks in advance, Tao 5/11/99 -- **********

Combined neutron/x-ray refinements

1999-05-07 Thread Brian H. Toby
(see http://www.ncnr.nist.gov/~toby/bt1.html). ******** Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975-4297 National Institute of

Re: Comments on Importance of matching software with hardware

1999-03-25 Thread Brian H. Toby
Plotting in Q sounds good to me.

Re: looking for ICSD data...

1999-03-10 Thread Brian H. Toby
I can understand the annoyance that is raised w/r to the industrial cost for ICSD. My pet peeve (as a former industrial chemist) was the cost for the Cambridge Crystal Structure Database, where academic users could get it for some small amount ($500 for a site license as I recall) and industrial

Re: structure factors calculation

1999-03-05 Thread Brian H. Toby
ve analysis. Does someone know where differences come from? Which software is the more reliable? Patrick Weisbecker Laboratoire de Science et Genie des Materiaux metalliques Ecole des Mines de Nancy e-mail: [EMAIL PROTECTED] -- ******

Re: looking for ICSD data...

1999-02-23 Thread Brian H. Toby
for the crystallographic community and one of scientific integrity. Brian Brian H. Toby, Ph.D.Leader, Crystallography Team [EMAIL PROTECTED] NIST Center for Neutron Research, Stop 8562 voice: 301-975