Hi, I have three intranet subnets by a central site with sipx server
(192.168.2.0/24 ) and two of branch sites (192.168.8.0/24 and
192.168.10.0/24) with VPN tunnel interconnections of hub-and-spoke.

The sip phones inside these three intranet subnets can make call to each
other without problem, and the remote worker also can make call to the sip
phone inside the subnet of sipx server. 

Whereas, when the remote worker calls to the sip phone inside the
second/third intranets, the called party rings but has only one-way audio
from remote work to called party. 

Is there anything related to the sipXbridge settings ?

Regards,

Jun

_______________________________________________
sipx-users mailing list sipx-users@list.sipfoundry.org
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to