Please make sure that your 192.168.8.0/24 and 192.168.10.0/24 appear in your intranet subnet list under System->Intranet Calling. The rule of thumb here is that the Intranet Subnets section should contain all the subnets that describe your intranet.
> > Hi, I have three intranet subnets by a central site with sipx server > (192.168.2.0/24 ) and two of branch sites (192.168.8.0/24 and > 192.168.10.0/24) with VPN tunnel interconnections of hub-and-spoke. > > The sip phones inside these three intranet subnets can make > call to each other without problem, and the remote worker > also can make call to the sip phone inside the subnet of sipx server. > > Whereas, when the remote worker calls to the sip phone inside > the second/third intranets, the called party rings but has > only one-way audio from remote work to called party. > > Is there anything related to the sipXbridge settings ? > > Regards, > > Jun > > _______________________________________________ > sipx-users mailing list sipx-users@list.sipfoundry.org List > Archive: http://list.sipfoundry.org/archive/sipx-users > Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users > sipXecs IP PBX -- http://www.sipfoundry.org/ > _______________________________________________ sipx-users mailing list sipx-users@list.sipfoundry.org List Archive: http://list.sipfoundry.org/archive/sipx-users Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users sipXecs IP PBX -- http://www.sipfoundry.org/