Please make sure that your 192.168.8.0/24 and 192.168.10.0/24 appear in
your intranet subnet list under System->Intranet Calling.  The rule of
thumb here is that the Intranet Subnets section should contain all the
subnets that describe your intranet.

> 
> Hi, I have three intranet subnets by a central site with sipx server
> (192.168.2.0/24 ) and two of branch sites (192.168.8.0/24 and
> 192.168.10.0/24) with VPN tunnel interconnections of hub-and-spoke.
> 
> The sip phones inside these three intranet subnets can make 
> call to each other without problem, and the remote worker 
> also can make call to the sip phone inside the subnet of sipx server. 
> 
> Whereas, when the remote worker calls to the sip phone inside 
> the second/third intranets, the called party rings but has 
> only one-way audio from remote work to called party. 
> 
> Is there anything related to the sipXbridge settings ?
> 
> Regards,
> 
> Jun
> 
> _______________________________________________
> sipx-users mailing list sipx-users@list.sipfoundry.org List 
> Archive: http://list.sipfoundry.org/archive/sipx-users
> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
> sipXecs IP PBX -- http://www.sipfoundry.org/
> 
_______________________________________________
sipx-users mailing list sipx-users@list.sipfoundry.org
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/

Reply via email to