Yes all of my three intranet subnets, 192.168.2.0/24, 192.168.8.0/24 and
192.168.10.0/24, were already set in the "Intranet Calling".

-----Original Message-----
From: Robert Joly [mailto:rj...@nortel.com] 
Sent: Monday, July 20, 2009 9:57 PM
To: jun,wen; sipx-users@list.sipfoundry.org
Subject: RE: [sipx-users] Remote worker cannot call to second intranet
subnets

Please make sure that your 192.168.8.0/24 and 192.168.10.0/24 appear in your
intranet subnet list under System->Intranet Calling.  The rule of thumb here
is that the Intranet Subnets section should contain all the subnets that
describe your intranet.

> 
> Hi, I have three intranet subnets by a central site with sipx server
> (192.168.2.0/24 ) and two of branch sites (192.168.8.0/24 and
> 192.168.10.0/24) with VPN tunnel interconnections of hub-and-spoke.
> 
> The sip phones inside these three intranet subnets can make call to 
> each other without problem, and the remote worker also can make call 
> to the sip phone inside the subnet of sipx server.
> 
> Whereas, when the remote worker calls to the sip phone inside the 
> second/third intranets, the called party rings but has only one-way 
> audio from remote work to called party.
> 
> Is there anything related to the sipXbridge settings ?
> 
> Regards,
> 
> Jun
> 
> _______________________________________________
> sipx-users mailing list sipx-users@list.sipfoundry.org List
> Archive: http://list.sipfoundry.org/archive/sipx-users
> Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
> sipXecs IP PBX -- http://www.sipfoundry.org/
> 

_______________________________________________
sipx-users mailing list sipx-users@list.sipfoundry.org
List Archive: http://list.sipfoundry.org/archive/sipx-users
Unsubscribe: http://list.sipfoundry.org/mailman/listinfo/sipx-users
sipXecs IP PBX -- http://www.sipfoundry.org/