Oh.. the "Real Telecom Players"... vs all those that have provided internet all over the place that the "Real Telecom Players" thumbed their noses at... Sorry that concept doesn't mean sweet thoughts to me... But yes 48V is the sweet spot, I just can't get behind -48v... Even when science To me it just means a way to jack prices...

On 06/21/2018 10:59 AM, ch...@wbmfg.com wrote:
It was always 48 for the real telecom players.
*From:* Josh Luthman
*Sent:* Thursday, June 21, 2018 11:52 AM
*To:* Mathew Howard
*Cc:* Chuck McCown ; AFMUG
*Subject:* Re: [AFMUG] ePMP voltages again - specifically 2ghz
It was 48v
Then it was mostly 24v
Now it's going 48v
Just give it a little bit, it'll go back to 24v.
I'd rather get a power supply doing 26v to fix my problem in 2 minutes than start changing things to 48v which would blow so much stuff up (epmp non gps, ubnt M gear, half the Mikrotiks)
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Thu, Jun 21, 2018 at 1:05 PM, Mathew Howard <mhoward...@gmail.com> wrote:

    No, there's not really a good reason, it just means you have an
    extra part to deal with.
    We still use UBNT for our 2.4ghz stuff, but those are the only
    radios that won't run off 48v on most of our new sites, so I've done
    some that are 48v only and just use those things on the radios that
    need them. But if you have more than 1 or 2 things that need 24v,
    it's generally more practical to just use a bigger voltage converter
    and run multiple radios off it.
    On Thu, Jun 21, 2018 at 11:57 AM, <ch...@wbmfg.com> wrote:

        Yep, that was what I was thinking.
        So, looks to me like there is no reason not to do 48 volts.
        *From:* Mathew Howard
        *Sent:* Thursday, June 21, 2018 10:56 AM
        *To:* Chuck McCown
        *Cc:* Dave ; AFMUG
        *Subject:* Re: [AFMUG] ePMP voltages again - specifically 2ghz
        You mean like this?
        https://www.ubnt.com/accessories/instant-8023af-adapters/
        <https://www.ubnt.com/accessories/instant-8023af-adapters/>
        Or do you have something better in mind?
        On Thu, Jun 21, 2018 at 11:53 AM, <ch...@wbmfg.com> wrote:

            Me too...
            So, what appetite is there for an inline POE regulator that
            would convert 48 to 24?
            *From:* Mathew Howard
            *Sent:* Thursday, June 21, 2018 10:50 AM
            *To:* Dave
            *Cc:* AFMUG
            *Subject:* Re: [AFMUG] ePMP voltages again - specifically 2ghz
            ugh... I keep forgetting to use reply-to-all...
            Not every single UBNT radio... all the airfibers will
            happily take 48v. Mikrotik is finally starting to make most
            of the new stuff handle 48v (including the PowerBox Pro),
            but yeah. UBNT is the reason I still have to use 24v on most
            of our towers... they make a converter you can stick on in
            line with the radios, but that's kind of a pain if you have
            more than one or two, and it's an extra part to fail.
            On Thu, Jun 21, 2018 at 11:46 AM, Dave <dmilho...@wletc.com>
            wrote:

                They make dental floss for that  :)


                On 06/21/2018 11:39 AM, Josh Luthman wrote:
                Except for every single Ubnt device and a majority of
                Mikrotiks....
                Josh Luthman
                Office: 937-552-2340
                Direct: 937-552-2343
                1100 Wayne St
                
<https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+%0D%0A++++45373&entry=gmail&source=g>
                Suite 1337
                
<https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+%0D%0A++++45373&entry=gmail&source=g>
                Troy, OH 45373
                
<https://maps.google.com/?q=1100+%0D%0A++++++Wayne+St+Suite+%0D%0A++++++1337+Troy,+OH+45373&entry=gmail&source=g>
                On Thu, Jun 21, 2018 at 12:39 PM, Josh Baird
                <joshba...@gmail.com> wrote:

                    I promise life will be easier if you just use 48V.  :)
                    On Thu, Jun 21, 2018 at 12:35 PM, Josh Luthman
                    <j...@imaginenetworksllc.com> wrote:

                        I'm trying to use a Powerbox Pro to power up
                        two epmp APs.  The 5 GHz is just fine but the
                        2 GHz is saying current too low.  Both ports
                        are getting 23 volts and the cables are <10
                        feet (from the Powerbox Pro).
                        Does anyone know if the 2ghz requires more
                        voltage possibly?
                        Spec sheet does say 23 volts min but it's
                        weird one powers (5 ghz) and the other doesn't.
                        Josh Luthman
                        Office: 937-552-2340
                        Direct: 937-552-2343
                        1100 Wayne St
                        
<https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
                        Suite 1337
                        
<https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
                        Troy, OH 45373
                        
<https://maps.google.com/?q=1100+Wayne+St+Suite+1337+Troy,+OH+45373&entry=gmail&source=g>
-- AF mailing list
                        AF@af.afmug.com
                        http://af.afmug.com/mailman/listinfo/af_af.afmug.com
                        <http://af.afmug.com/mailman/listinfo/af_af.afmug.com>




-- -- AF mailing list
                AF@af.afmug.com
                http://af.afmug.com/mailman/listinfo/af_af.afmug.com
                <http://af.afmug.com/mailman/listinfo/af_af.afmug.com>

            
------------------------------------------------------------------------
-- AF mailing list
            AF@af.afmug.com
            http://af.afmug.com/mailman/listinfo/af_af.afmug.com
            <http://af.afmug.com/mailman/listinfo/af_af.afmug.com>


-- AF mailing list
    AF@af.afmug.com
    http://af.afmug.com/mailman/listinfo/af_af.afmug.com
    <http://af.afmug.com/mailman/listinfo/af_af.afmug.com>




--
AF mailing list
AF@af.afmug.com
http://af.afmug.com/mailman/listinfo/af_af.afmug.com

Reply via email to