Put surge suppressors within 3' of the radio on the tower as well. Motorola recommended that forever and more recently UBNT started recommending that.

On 10/25/2015 12:13 PM, Gino Villarini wrote:
Yes

On Sunday, October 25, 2015, Josh Luthman <j...@imaginenetworksllc.com <mailto:j...@imaginenetworksllc.com>> wrote:

    Shielded cable to the SS for sure...

    Have you looked at doing fiber/DC up the tower and then distribute
    it out that way?


    Josh Luthman
    Office: 937-552-2340
    Direct: 937-552-2343
    1100 Wayne St
    Suite 1337
    Troy, OH 45373

    On Sun, Oct 25, 2015 at 11:57 AM, Gino Villarini
    <ginovi...@gmail.com> wrote:

        So we are loosing radios left and right due to lightning!

        Typical site setup:

        Radios on tower grounded to tower

        Shielded cable

        Shielded patch panel - grounded

        Regular cat5 jumpers

        Wbmfg SS - grounded

        Regular cat5 jumpers

        Poe device

        What's wrong?