Speaking of fuses, I know sometimes we get overcurrent trips on CTMs and
SyncInjectors and have to reset them. Very rare, but always during storms.
It is possible this is saving radios, I can't say for sure.
-----Original Message-----
From: George Skorup
Sent: Sunday, October 25, 2015 12:34 PM
To: af@afmug.com
Subject: Re: [AFMUG] Site Grounding - what we are doing wrong?
One thing we've been doing for several years now is a bonding wire up
the tower. I do not trust the tower steel/leg joints being low enough
resistance. Failure rate went way down. DC and fuses doesn't hurt either.
On 10/25/2015 10:57 AM, Gino Villarini wrote:
So we are loosing radios left and right due to lightning!
Typical site setup:
Radios on tower grounded to tower
Shielded cable
Shielded patch panel - grounded
Regular cat5 jumpers
Wbmfg SS - grounded
Regular cat5 jumpers
Poe device
What's wrong?