Nice. I like when problems are simple to solve like that.
On 10/29/2015 11:28 AM, Josh Luthman wrote:
Not a stupid question, George. That was it.
Factory default is actually the second to last option - auto
100/10/f/h. I mean config from the factory - not what happens if you
push factory default in software. I did take this radio from 14.0
(factory) to 14.1b6.
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Thu, Oct 29, 2015 at 7:20 AM, Forrest Christian (List Account)
<li...@packetflux.com <mailto:li...@packetflux.com>> wrote:
Good catch... My testing 450i seems to default to gigabit off
(after a factory default).
Once I set it on (which I seem to remember doing previously as
well), it links right up at gigabit speeds. This is with a RB850Gx2
-forrest
On Wed, Oct 28, 2015 at 5:32 PM, George Skorup <geo...@cbcast.com
<mailto:geo...@cbcast.com>> wrote:
Stupid question.... Does the 450i have this like 13.x on the
regular 450? Default is auto 100f/100h/10f/10h.
On 10/28/2015 4:37 PM, Josh Luthman wrote:
I wonder if this unit is capable of doing gigabit with 450i?
It does gigabit on the ePMP.
Josh Luthman
Office: 937-552-2340 <tel:937-552-2340>
Direct: 937-552-2343 <tel:937-552-2343>
1100 Wayne St
Suite 1337
Troy, OH 45373
On Wed, Oct 28, 2015 at 5:36 PM, Matt
<matt.mailingli...@gmail.com
<mailto:matt.mailingli...@gmail.com>> wrote:
> I have a PacketFlux SyncInjector Gigabit that goes to the
450i. It's got a
> 48v power supply. There is no syncpipe, nor would
anything work in the lab.
> The test PC has two Intel gigabit NICs.
>
> My issue is that I can only get a 100 Mbit here.
>
> I have it set to generate sync right now and I can
access it just fine. If
> I have it set for autosync + free run I get some
problems accessing the
> device (ping works for a few seconds on, then off, web
interface is not
> responsive at all, CNUT flat out doesn't work). The
ethernet link does not
> go down/up with sync at all.
>
> Any other clues or things to look at?
FYI, I am seeing same thing. It passes through a
GigE-APC-HV on way
to 450i AP. AP is getting sync from daisy chained
syncpipe source
hooked too Gigabit SyncInjector powered by 48 volt. AP
is working
fine just at 100mbps ethernet.
--
*Forrest Christian* /CEO//, PacketFlux Technologies, Inc./
Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
forre...@imach.com <mailto:forre...@imach.com> |
http://www.packetflux.com <http://www.packetflux.com/>
<http://www.linkedin.com/in/fwchristian>
<http://facebook.com/packetflux> <http://twitter.com/@packetflux>