Nice. I like when problems are simple to solve like that.

On 10/29/2015 11:28 AM, Josh Luthman wrote:
Not a stupid question, George.  That was it.

Factory default is actually the second to last option - auto 100/10/f/h. I mean config from the factory - not what happens if you push factory default in software. I did take this radio from 14.0 (factory) to 14.1b6.


Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373

On Thu, Oct 29, 2015 at 7:20 AM, Forrest Christian (List Account) <li...@packetflux.com <mailto:li...@packetflux.com>> wrote:

    Good catch... My testing 450i seems to default to gigabit off
    (after a factory default).

    Once I set it on (which I seem to remember doing previously as
    well), it links right up at gigabit speeds.  This is with a RB850Gx2

    -forrest






    On Wed, Oct 28, 2015 at 5:32 PM, George Skorup <geo...@cbcast.com
    <mailto:geo...@cbcast.com>> wrote:

        Stupid question.... Does the 450i have this like 13.x on the
        regular 450? Default is auto 100f/100h/10f/10h.



        On 10/28/2015 4:37 PM, Josh Luthman wrote:
I wonder if this unit is capable of doing gigabit with 450i? It does gigabit on the ePMP.


        Josh Luthman
        Office: 937-552-2340 <tel:937-552-2340>
        Direct: 937-552-2343 <tel:937-552-2343>
        1100 Wayne St
        Suite 1337
        Troy, OH 45373

        On Wed, Oct 28, 2015 at 5:36 PM, Matt
        <matt.mailingli...@gmail.com
        <mailto:matt.mailingli...@gmail.com>> wrote:

            > I have a PacketFlux SyncInjector Gigabit that goes to the
            450i. It's got a
            > 48v power supply.  There is no syncpipe, nor would
            anything work in the lab.
            > The test PC has two Intel gigabit NICs.
            >
            > My issue is that I can only get a 100 Mbit here.
            >
            > I have it set to generate sync right now and I can
            access it just fine.  If
            > I have it set for autosync + free run I get some
            problems accessing the
            > device (ping works for a few seconds on, then off, web
            interface is not
            > responsive at all, CNUT flat out doesn't work).  The
            ethernet link does not
            > go down/up with sync at all.
            >
            > Any other clues or things to look at?

            FYI, I am seeing same thing. It passes through a
            GigE-APC-HV on way
            to 450i AP.  AP is getting sync from daisy chained
            syncpipe source
            hooked too Gigabit SyncInjector powered by 48 volt.  AP
            is working
            fine just at 100mbps ethernet.






-- *Forrest Christian* /CEO//, PacketFlux Technologies, Inc./
    Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602
    forre...@imach.com <mailto:forre...@imach.com> |
    http://www.packetflux.com <http://www.packetflux.com/>
    <http://www.linkedin.com/in/fwchristian>
    <http://facebook.com/packetflux> <http://twitter.com/@packetflux>




Reply via email to