This is what I'm using and I did make it work (after I set it to do auto 1000 from default auto 100). Forrest - please correct the notes to say up to 57 =)
http://store.packetflux.com/gigabit-syncinjector-for-24-volt-cambium-radios/ Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Thu, Oct 29, 2015 at 3:21 PM, Forrest Christian (List Account) < li...@packetflux.com> wrote: > Which injector are you using? > > On Oct 29, 2015 11:05 AM, "Matt" <matt.mailingli...@gmail.com> wrote: > > > > I have mine set on 1000base and it will only do 100base. It tries to do > 1000base at first, you can see the dlink managed switch light blink green > at first, then it gives up and goes too 100base. It passes through 200 > foot of shielded cat-5 then a GigE-APC-HV. I have also tried a 430APC-HV > with same result. > > > > > > On Thu, Oct 29, 2015 at 11:28 AM, Josh Luthman < > j...@imaginenetworksllc.com> wrote: > >> > >> Not a stupid question, George. That was it. > >> > >> Factory default is actually the second to last option - auto > 100/10/f/h. I mean config from the factory - not what happens if you push > factory default in software. I did take this radio from 14.0 (factory) to > 14.1b6. > >> > >> > >> Josh Luthman > >> Office: 937-552-2340 > >> Direct: 937-552-2343 > >> 1100 Wayne St > >> Suite 1337 > >> Troy, OH 45373 > >> > >> On Thu, Oct 29, 2015 at 7:20 AM, Forrest Christian (List Account) < > li...@packetflux.com> wrote: > >>> > >>> Good catch... My testing 450i seems to default to gigabit off (after a > factory default). > >>> > >>> Once I set it on (which I seem to remember doing previously as well), > it links right up at gigabit speeds. This is with a RB850Gx2 > >>> > >>> -forrest > >>> > >>> > >>> > >>> > >>> > >>> > >>> On Wed, Oct 28, 2015 at 5:32 PM, George Skorup <geo...@cbcast.com> > wrote: > >>>> > >>>> Stupid question.... Does the 450i have this like 13.x on the regular > 450? Default is auto 100f/100h/10f/10h. > >>>> > >>>> > >>>> > >>>> On 10/28/2015 4:37 PM, Josh Luthman wrote: > >>>>> > >>>>> I wonder if this unit is capable of doing gigabit with 450i? It > does gigabit on the ePMP. > >>>>> > >>>>> > >>>>> Josh Luthman > >>>>> Office: 937-552-2340 > >>>>> Direct: 937-552-2343 > >>>>> 1100 Wayne St > >>>>> Suite 1337 > >>>>> Troy, OH 45373 > >>>>> > >>>>> On Wed, Oct 28, 2015 at 5:36 PM, Matt <matt.mailingli...@gmail.com> > wrote: > >>>>>> > >>>>>> > I have a PacketFlux SyncInjector Gigabit that goes to the 450i. > It's got a > >>>>>> > 48v power supply. There is no syncpipe, nor would anything work > in the lab. > >>>>>> > The test PC has two Intel gigabit NICs. > >>>>>> > > >>>>>> > My issue is that I can only get a 100 Mbit here. > >>>>>> > > >>>>>> > I have it set to generate sync right now and I can access it just > fine. If > >>>>>> > I have it set for autosync + free run I get some problems > accessing the > >>>>>> > device (ping works for a few seconds on, then off, web interface > is not > >>>>>> > responsive at all, CNUT flat out doesn't work). The ethernet > link does not > >>>>>> > go down/up with sync at all. > >>>>>> > > >>>>>> > Any other clues or things to look at? > >>>>>> > >>>>>> FYI, I am seeing same thing. It passes through a GigE-APC-HV on way > >>>>>> to 450i AP. AP is getting sync from daisy chained syncpipe source > >>>>>> hooked too Gigabit SyncInjector powered by 48 volt. AP is working > >>>>>> fine just at 100mbps ethernet. > >>>>> > >>>>> > >>>> > >>> > >>> > >>> > >>> -- > >>> Forrest Christian CEO, PacketFlux Technologies, Inc. > >>> Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602 > >>> forre...@imach.com | http://www.packetflux.com > >>> > >>> > >> > > > >