Not a stupid question, George. That was it. Factory default is actually the second to last option - auto 100/10/f/h. I mean config from the factory - not what happens if you push factory default in software. I did take this radio from 14.0 (factory) to 14.1b6.
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Thu, Oct 29, 2015 at 7:20 AM, Forrest Christian (List Account) < li...@packetflux.com> wrote: > Good catch... My testing 450i seems to default to gigabit off (after a > factory default). > > Once I set it on (which I seem to remember doing previously as well), it > links right up at gigabit speeds. This is with a RB850Gx2 > > -forrest > > > > > > > On Wed, Oct 28, 2015 at 5:32 PM, George Skorup <geo...@cbcast.com> wrote: > >> Stupid question.... Does the 450i have this like 13.x on the regular 450? >> Default is auto 100f/100h/10f/10h. >> >> >> >> On 10/28/2015 4:37 PM, Josh Luthman wrote: >> >> I wonder if this unit is capable of doing gigabit with 450i? It does >> gigabit on the ePMP. >> >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> >> On Wed, Oct 28, 2015 at 5:36 PM, Matt <matt.mailingli...@gmail.com> >> wrote: >> >>> > I have a PacketFlux SyncInjector Gigabit that goes to the 450i. It's >>> got a >>> > 48v power supply. There is no syncpipe, nor would anything work in >>> the lab. >>> > The test PC has two Intel gigabit NICs. >>> > >>> > My issue is that I can only get a 100 Mbit here. >>> > >>> > I have it set to generate sync right now and I can access it just >>> fine. If >>> > I have it set for autosync + free run I get some problems accessing the >>> > device (ping works for a few seconds on, then off, web interface is not >>> > responsive at all, CNUT flat out doesn't work). The ethernet link >>> does not >>> > go down/up with sync at all. >>> > >>> > Any other clues or things to look at? >>> >>> FYI, I am seeing same thing. It passes through a GigE-APC-HV on way >>> to 450i AP. AP is getting sync from daisy chained syncpipe source >>> hooked too Gigabit SyncInjector powered by 48 volt. AP is working >>> fine just at 100mbps ethernet. >>> >> >> >> > > > -- > *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.* > Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602 > forre...@imach.com | http://www.packetflux.com > <http://www.linkedin.com/in/fwchristian> <http://facebook.com/packetflux> > <http://twitter.com/@packetflux> > >