I kind of agree. I'm not sure the idea was behind defaulting it to auto 100 instead of auto 1000, though...
Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Thu, Oct 29, 2015 at 2:40 PM, George Skorup <geo...@cbcast.com> wrote: > Nice. I like when problems are simple to solve like that. > > On 10/29/2015 11:28 AM, Josh Luthman wrote: > > Not a stupid question, George. That was it. > > Factory default is actually the second to last option - auto 100/10/f/h. > I mean config from the factory - not what happens if you push factory > default in software. I did take this radio from 14.0 (factory) to 14.1b6. > > > Josh Luthman > Office: 937-552-2340 > Direct: 937-552-2343 > 1100 Wayne St > Suite 1337 > Troy, OH 45373 > > On Thu, Oct 29, 2015 at 7:20 AM, Forrest Christian (List Account) < > <li...@packetflux.com>li...@packetflux.com> wrote: > >> Good catch... My testing 450i seems to default to gigabit off (after a >> factory default). >> >> Once I set it on (which I seem to remember doing previously as well), it >> links right up at gigabit speeds. This is with a RB850Gx2 >> >> -forrest >> >> >> >> >> >> >> On Wed, Oct 28, 2015 at 5:32 PM, George Skorup < <geo...@cbcast.com> >> geo...@cbcast.com> wrote: >> >>> Stupid question.... Does the 450i have this like 13.x on the regular >>> 450? Default is auto 100f/100h/10f/10h. >>> >>> >>> >>> On 10/28/2015 4:37 PM, Josh Luthman wrote: >>> >>> I wonder if this unit is capable of doing gigabit with 450i? It does >>> gigabit on the ePMP. >>> >>> >>> Josh Luthman >>> Office: 937-552-2340 >>> Direct: 937-552-2343 >>> 1100 Wayne St >>> Suite 1337 >>> Troy, OH 45373 >>> >>> On Wed, Oct 28, 2015 at 5:36 PM, Matt < <matt.mailingli...@gmail.com> >>> matt.mailingli...@gmail.com> wrote: >>> >>>> > I have a PacketFlux SyncInjector Gigabit that goes to the 450i. It's >>>> got a >>>> > 48v power supply. There is no syncpipe, nor would anything work in >>>> the lab. >>>> > The test PC has two Intel gigabit NICs. >>>> > >>>> > My issue is that I can only get a 100 Mbit here. >>>> > >>>> > I have it set to generate sync right now and I can access it just >>>> fine. If >>>> > I have it set for autosync + free run I get some problems accessing >>>> the >>>> > device (ping works for a few seconds on, then off, web interface is >>>> not >>>> > responsive at all, CNUT flat out doesn't work). The ethernet link >>>> does not >>>> > go down/up with sync at all. >>>> > >>>> > Any other clues or things to look at? >>>> >>>> FYI, I am seeing same thing. It passes through a GigE-APC-HV on way >>>> to 450i AP. AP is getting sync from daisy chained syncpipe source >>>> hooked too Gigabit SyncInjector powered by 48 volt. AP is working >>>> fine just at 100mbps ethernet. >>>> >>> >>> >>> >> >> >> -- >> *Forrest Christian* *CEO**, PacketFlux Technologies, Inc.* >> Tel: 406-449-3345 | Address: 3577 Countryside Road, Helena, MT 59602 >> <forre...@imach.com>forre...@imach.com | <http://www.packetflux.com/> >> http://www.packetflux.com >> <http://www.linkedin.com/in/fwchristian> >> <http://facebook.com/packetflux> <http://twitter.com/@packetflux> >> >> > >