Question: would it work if the connection was _after_ (i.e. downstream of) the 
pump (separate suction hoses, discharge hoses T-d to a single through hull)?

Marek

From: Rick Brass via CnC-List
Sent: Wednesday, May 2, 2018 11:44
To: cnc-list@cnc-list.com
Cc: Rick Brass
Subject: Re: Stus-List C&C 33 MK II Bilge pumps

I can see some almost neurotic logic to having two large manual pumps – 
redundancy if one fails or just having a lot of capacity in case you really 
need to dewater in an emergency. (I actually have a Whale Gusher in the garage 
that I plan to take aboard as a portable emergency pump when I go cruising.)

But having two pumps on the same hose makes no sense. What if one pump fails? 
That could make redundant pumps absolutely useless.

I suspect the suggestion that there were originally two separate pumps with two 
hoses and two through hulls is the correct answer ….. and the best practice.

Rick Brass
Washington, NC