My setup is charging a 33 AH AGM battery via a West Mountain Radio PowerGate
PG40S that feeds a distribution panel for the K3, P3 and other 12v
accessories. The power supply input to the PowerGate is a PowerWerx
SPS-30DM. The system can handle short power outages and keeps the battery
correctly charged. I only turn the P/S on when using the rigs unless the
PowerGate indicates a need for 'bulk' charging. When it goes to float, I
turn the P/S off. I really see this as an uninterruptible P/S protection for
the station. It was also helpful when I was chasing down an interference
signal I was seeing by eliminating any source in the house (cut the AC mains
and ran the K3/P3 form the battery.)

73 ..mike AI6II



--
View this message in context: 
http://elecraft.365791.n2.nabble.com/K3-13-8-VDC-power-tp7596240p7596302.html
Sent from the Elecraft mailing list archive at Nabble.com.
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to arch...@mail-archive.com

Reply via email to