On 3/18/2019 2:38 PM, Tom Georgens wrote:
Admittedly 1.15:1 is not world class, and could be better, but I don't consider 
it unacceptable and I plan on using the switches I bought.  Are we drawing 
different conclusions from the same data?

Hi Tom,

Yes, we are. I was using a pair of them to switch inputs and outputs of a KPA500 an Ten Tec Titan. I use the KPA mostly on 6M, and what you saw on 10M was significantly worse there.

Another important point. It is totally unrealistic to terminate un-used ports for isolation measurements, because un-used ports are often not matched at the frequency where isolation is of concern. I measure isolation between ports with a VNA (the DG8SAQ VNWA3e). In the case of this unit, I would measure between the two outputs.

73, Jim

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html

Reply via email to