On Sun, 2011-04-03 at 10:52 -0400, gene heskett wrote:
... snip
> I would have a hard time justifying an idling current draw of 35 amps a leg 
> from the 240 to run a 3 horse motor on the machine.

This links covers a remote start setup:
http://homemetalshopclub.org/projects/phconv/phconv.html 

This one is new to me:
http://hmin.tripod.com/als/andysm/pages/3phase02.html 

looks similar to John's schematic.

I used this link for mine:
http://www.metalwebnews.com/howto/ph-conv/ph-conv.html 

It seems that if I were clever enough, there might be a way to have a
low voltage on the converter output that could sense when a machine is
turned on, then start the converter, switch in the high voltage, then
shut down when no load is sensed. My converter is close to the machine I
use it with, so I just turn it on and off as needed.
-- 
Kirk Wallace
http://www.wallacecompany.com/machine_shop/
http://www.wallacecompany.com/E45/index.html
California, USA


------------------------------------------------------------------------------