On Fri, Oct 07, 2011 at 08:48:33PM -0700, Bruce Klawiter wrote:
> 
> The machine did not dither or do the jerking with the old Anilam
> control.Someone said the axis might be drifting then snap back into
> position, I put an indicator on an axis and it holds position and when
> it jerks it moves about .002" out of position then back, hard to tell
> it so fast.

That's really weird, and sounds more sinister than noise on the
encoder signals.


------------------------------------------------------------------------------