Well, duh.  I should have checked the VSE ADD statement, it's a
1403!!!!!!  Your reply was right on the money. THANK YOU.  

Dave Jones wrote:

<snip
I suspect that your problem isn't with your CMS Reader settings but with

how the virtual printer is defined to your VSE guests. If the VSE guest 
virtual printer is defined as a 1403 then anything "printed" to tht 
device will be truncated at 132 characters, the maximum line length the 
1403 could print.

Try defining the virtual printer for the VSE guest as a 3800 instead....

   SPOOL  00E 3800 ....

The 3800 supports (supported?) print lines up to 204 characters in
length.

Reply via email to