Standard pc ports dont support 76800 do they? On Sunday, April 26, 2020, Stephen Adolph <twospru...@gmail.com> wrote:
> I know that Ken, Nothing else can though? > > > On Sunday, April 26, 2020, Ken Pettit <petti...@gmail.com> wrote: > >> Hey Steve, >> >> M100 can run at 76800 on it's UART. >> >> Ken >> >> On 4/26/20 2:39 AM, Stephen Adolph wrote: >> >> John what are you connecting to at 76800? I dont think I have anything >> other than an m100. >> >> >> On Sunday, April 26, 2020, John R. Hogerhuis <jho...@pobox.com> wrote: >> >>> >>> >>> On Sat, Apr 25, 2020 at 7:25 PM Stephen Adolph <twospru...@gmail.com> >>> wrote: >>> >>>> Still playing around with the BCR TTL serial port. >>>> ...yes it has it's limitations... half duplex, no flow control, >>>> bit-banged >>>> >>>> ..but it is fast! Today I was able to get 32kB transferred in 7 >>>> seconds. That's pretty close to 100% utilization on the 57600 baud line. >>>> >>>> >>> Very cool :-) >>> >>> >>>> I think that is a new M100 record. It might need independent >>>> verification! >>>> >>> >>> Close! >>> >>> I just measured TBACK.EXE at 76800bps dumps all 32K to a PC in >>> 6.56seconds. >>> >>> > .\TBACK.EXE -b -f COM9 ABACK.CB >>> >>> At 19200 it's like 9 seconds. >>> >>> :-) >>> >>> TBACK.EXE has you RUN"COM:98N1E" and it injects a small program that >>> bootstraps up to 76800bps and then blasts the data out the port. >>> >>> -- John. >>> >> >>