hi,
I've printed some barcodes for our LTO-2 Autochanger which is also used for
Amanda. For testing I want to label the tapes from 001 till 020 and not more:
[..]
3: Autochanger
Select Storage resource (1-3): 3
Connecting to Storage daemon Autochanger at backup:9103 ...
3306 Issuing
Denny Schierz schrieb:
hi,
I've printed some barcodes for our LTO-2 Autochanger which is also used for
Amanda. For testing I want to label the tapes from 001 till 020 and not more:
[..]
better use 'label barcode slots 1-20'
Ralf
I have just added 10 unlabeled, barcoded tape to a library that contains
10 labeled, barcoded tapes.
From the bat application, I have issued the following commands:
update slots
label barcodes
At this point the bat console shows a list of the tapes that will be
labelled, but this includes
On Sun, Jul 25, 2010 at 5:38 PM, Richard Scobie rich...@sauce.co.nz wrote:
I have just added 10 unlabeled, barcoded tape to a library that contains
10 labeled, barcoded tapes.
From the bat application, I have issued the following commands:
update slots
label barcodes
At this point the
John Drescher wrote:
Also, in this scenario, are the tapes labeled in ascending slot order or
ascending barcode order?
The latter.
Actually it is labeling them in slot order which is annoying. In future
I will remember to load all the tapes with ascendinging barcode numbers
in ascending
On Sun, Jul 25, 2010 at 7:55 PM, Richard Scobie rich...@sauce.co.nz wrote:
John Drescher wrote:
Also, in this scenario, are the tapes labeled in ascending slot order or
ascending barcode order?
The latter.
Actually it is labeling them in slot order which is annoying. In future I
will
Hi,
I have an IBM TS3310 (rebadged Quantum Scalar i500), however, I don't
think your problem is specific to the hardware.
First, can you make sure that your drive numbering is correct? Is
drive 0 in fact /dev/nst0? On my systems, sometimes they get mapped
differently on reboot because
Hi
I hope someone can help me or point me in the right direction. I have a bran
new Quantum Scalar i500 with 5 drives and 125 slots. When ever I try to do
label barcodes it fails with timeout errors. Bacula is reading the barcodes
from the tape drive but is not labeling it.
ekke85 wrote:
Hi
I hope someone can help me or point me in the right direction. I have a bran
new Quantum Scalar i500 with 5 drives and 125 slots. When ever I try to do
label barcodes it fails with timeout errors. Bacula is reading the barcodes
from the tape drive but is not labeling
On 02/ 4/10 10:20 AM, Thomas Dhollander wrote:
Dear all
I have a few questions regarding the labeling of volumes in bacula release
3.0.3:
As we are using an IBM TS2900 autochanger, i had set label type to 'IBM'.
However, the label barcodes command now fails because Bacula tries to assign
Dear all
I have a few questions regarding the labeling of volumes in bacula release
3.0.3:
As we are using an IBM TS2900 autochanger, i had set label type to 'IBM'.
However, the label barcodes command now fails because Bacula tries to assign
labels that are 8 characters long, while the
As we are using an IBM TS2900 autochanger, i had set label type to 'IBM'.
However, the label barcodes command now fails because Bacula tries to assign
labels that are 8 characters long, while the maximum is 6. Should we use IBM
labels or not? If so, is manual labeling required (rather than
Hi,
I use bacula 2.4.0 on Linux 2.6.9-42
I have Spectralogic T50 as Library and work as well from 2 years. My
LTO3 tape have barcodes.
I set the label of the tape LTO3 manually, if I like to use barcode
names the data on the tape was deleted?
Thank you.
--
Daniele Eccher
Gruppo Darco -
2009/9/21 Daniele Eccher daniele.ecc...@sociale.it:
Hi,
I use bacula 2.4.0 on Linux 2.6.9-42
I have Spectralogic T50 as Library and work as well from 2 years. My LTO3
tape have barcodes.
I set the label of the tape LTO3 manually, if I like to use barcode names
the data on the tape was
If I use the barcode I can mount the tape on always the 8 terapack I
have (each terapack have 5 tape inside), and i'm not bind to the slot
number.
Understand?
Thank you
Il giorno 21/set/09, alle ore 16:25, John Drescher ha scritto:
2009/9/21 Daniele Eccher daniele.ecc...@sociale.it:
Hi,
On Mon, Sep 21, 2009 at 10:28 AM, Daniele Eccher
daniele.ecc...@sociale.it wrote:
If I use the barcode I can mount the tape on always the 8 terapack I have
(each terapack have 5 tape inside), and i'm not bind to the slot number.
Understand?
I think I do now.
I believe putting a barcode label
Ok, therefore the label barcode use the barcode to label each tape in
the library but it's depends always that it's slot number. If i change
the tape position on the slot (example from 22 to 24), i have to do
update slots to see bacula the tape change position.
But there is a method to use
On Mon, Sep 21, 2009 at 10:40 AM, Daniele Eccher
daniele.ecc...@sociale.it wrote:
Ok, therefore the label barcode use the barcode to label each tape in the
library but it's depends always that it's slot number. If i change the tape
position on the slot (example from 22 to 24), i have to do
On Mon, 21 Sep 2009 15:40:08 +0200
Daniele Eccher daniele.ecc...@sociale.it wrote:
Hi,
I use bacula 2.4.0 on Linux 2.6.9-42
I have Spectralogic T50 as Library and work as well from 2 years. My
LTO3 tape have barcodes.
I set the label of the tape LTO3 manually, if I like to use
Dear John Drescher,
In message 387ee2020909210749o48d1fd07qd829c661ae7af...@mail.gmail.com you
wrote:
I believe putting a barcode label on a tape that already has a manual
label will not delete the tape however executing the label barcode
command will fail because the tape already has a
Alex Chekholko writes:
Whenever I want to reuse a tape that has already been used by Bacula, I
erase it first. Then I use it as if it was brand new. E.g. load it
and do an mt -f /dev/nst0 weof mt -f /dev/nst0 rewind then label
barcodes in bconsole.
the Bacula daemons should be stopped
Hi,
Arno Lehmann wrote:
Run it several times with different slot ranges, like
'label barcodes slots=1-3 pool=F01' and so on.
Brilliant - thank you. The fact that you can use slots and pool seems to
be missing from the docs, so I guess I should work on trying to add it :)
It only seems to
On Nov 8, 2007 7:20 PM, Chris Howells [EMAIL PROTECTED] wrote:
Hi,
Arno Lehmann wrote:
Run it several times with different slot ranges, like
'label barcodes slots=1-3 pool=F01' and so on.
Brilliant - thank you. The fact that you can use slots and pool seems to
be missing from the docs,
Hi,
I've defined pools F01, F02, ..., F10 in my director config.
I've loaded the autochanger with a pile of tapes which have a barcodef
name prefixed with the name of the pool I want to add it to.
So for instance tape F01T01L4 should go into pool F01, F09T02L4 should
go into pool F09.
Is
Hi,
07.11.2007 16:30,, Chris Howells wrote::
Hi,
I've defined pools F01, F02, ..., F10 in my director config.
I've loaded the autochanger with a pile of tapes which have a barcodef
name prefixed with the name of the pool I want to add it to.
So for instance tape F01T01L4 should go
Hello,
Today i tried to add a new tape to the pool:
*label barcodes slots=2
Automatically selected Storage: Autochanger
Connecting to Storage daemon Autochanger at backup:9103 ...
3306 Issuing autochanger slots command.
Device Drive-1 has 16 slots.
Connecting to Storage daemon Autochanger at
On 9/11/07, Robert Garwacki [EMAIL PROTECTED] wrote:
Hello,
Today i tried to add a new tape to the pool:
*label barcodes slots=2
Automatically selected Storage: Autochanger
Connecting to Storage daemon Autochanger at backup:9103 ...
3306 Issuing autochanger slots command.
Device Drive-1
Kern Sibbald wrote (2006/01/19):
--- src/dird/ua_label.c.origThu Jan 19 10:05:21 2006
+++ src/dird/ua_label.c Thu Jan 19 10:07:50 2006
@@ -305,7 +305,9 @@
}
if (!relabel (i=find_arg_keyword(ua, barcode_keyword)) = 0) {
- *ua-argk[i] = 0; /* zap barcode
On Tuesday 25 April 2006 16:52, Rudolf Cejka wrote:
Kern Sibbald wrote (2006/01/19):
--- src/dird/ua_label.c.orig Thu Jan 19 10:05:21 2006
+++ src/dird/ua_label.c Thu Jan 19 10:07:50 2006
@@ -305,7 +305,9 @@
}
if (!relabel (i=find_arg_keyword(ua,
Hi,
I just added some tapes to my autochanger. If I do a label barcodes
command, will it re-label the existing tapes too, or only label the new
tapes? The documentation isn't clear on that topic.
Figured I'd ask before I inadvertently wipe out the existing tapes...
Thanks,
Chris
Chris
Chris Wilson wrote:
Hi,
I just added some tapes to my autochanger. If I do a label barcodes
command, will it re-label the existing tapes too, or only label the new
tapes? The documentation isn't clear on that topic.
Figured I'd ask before I inadvertently wipe out the existing tapes...
It
On 8 Mar 2006 at 10:11, Gregory Orange wrote:
Chris Wilson wrote:
Hi,
I just added some tapes to my autochanger. If I do a label barcodes
command, will it re-label the existing tapes too, or only label the new
tapes? The documentation isn't clear on that topic.
Figured I'd ask
Greetings,
I installed version 1.38.5 this week and am thus far impressed! With
some tweaking, I have it interfacing w/ an ADIC Scalar 100 (50 slots)
housing one LTO-1 and one LTO-2 drive.
I have a few initial questions regarding this solution, and would
appreciate any advice:
1. How
Ian Levesque wrote:
Greetings,
I installed version 1.38.5 this week and am thus far impressed!
Good to hear!
With some tweaking, I have it interfacing w/ an ADIC Scalar 100 (50
slots) housing one LTO-1 and one LTO-2 drive.
Awesome. I run a Scalar 220 with AIT2 tapes, but LTO can't be
Dear Ryan, et al.,
Thank you for your response.
1. How should I manage the mixture of LTO-1 and LTO-2 tapes in the
ADIC with bacula? I set up two pools, one for each media type. I run
the label barcodes command to use the ADIC's barcode scanner to add
the tapes to the database, but this puts
Ian Levesque wrote:
Dear Ryan, et al.,
Thank you for your response.
1. How should I manage the mixture of LTO-1 and LTO-2 tapes in the
ADIC with bacula? I set up two pools, one for each media type. I run
the label barcodes command to use the ADIC's barcode scanner to add
the tapes to the
On Thursday 19 January 2006 10:27, Rudolf Cejka wrote:
Kern Sibbald wrote (2006/01/18):
I have tested both Bacula-1.38.3 and Bacula-1.38.4 now too:
Unfortunately they are broken as Bacula-1.38.2 too - the first
argument is discarded. As a workaround, you can use
label ANYTHING
Evan Kaufman wrote (2006/01/17):
Is the long syntax of the 'label barcodes' console command fully
functional?
Hello, interesting - I had exactly the same problem as you yesterday too :o)
It seems, that label [storage=xxx] [pool=yyy] [slots=1-10] barcodes is
broken in Bacula-1.38.2, but in
Hello,
On 1/18/2006 10:42 AM, Rudolf Cejka wrote:
Rudolf Cejka wrote (2006/01/18):
I wanted to test Bacula-1.38.3 and/or Bacula-1.38.4, however
I haven't sufficient time yet.
I have tested both Bacula-1.38.3 and Bacula-1.38.4 now too: Unfortunately
they are broken as Bacula-1.38.2 too -
Kern Sibbald wrote (2006/01/18):
I am unable to reproduce this on version 1.38.4, so if someone submits it to
the bugs database, be sure to include proof that there is a bug. You might
want to include output with the Director's debug level set to 400.
Ok, when my bacula server is idle, I'll
Is the long syntax of the 'label barcodes' console command fully
functional? In other words, can I specify the slots i want labeled,
in which storage resource, in which pool, all from a one-line
command?
From what i could understand from the manual, it should be something
similar to this:
label
41 matches
Mail list logo