> Use a 5-6V supply capable of 2 or 3 amps.
>
> Thanks, it's actually working fine, the led properly turned green after
the firmware and gateware were uploaded.

Trying  .\benchmark_rate.exe --rx_rate 40e6 I get
Benchmark rate summary:
  Num received samples:     201778444
  Num dropped samples:      2800
  Num overruns detected:    2800
  Num transmitted samples:  0
  Num sequence errors (Tx): 0
  Num sequence errors (Rx): 0
  Num underruns detected:   0
  Num late commands:        0
  Num timeouts (Tx):        0
  Num timeouts (Rx):        0

It seems I still can't stream faster than around 28MS/s. I still get
similar results with .\rx_samples_to_file.exe (using --null to not store to
file).

Should I try to run some tests from
http://files.ettus.com/manual/page_rdtesting.html ?

Concerning the error "[ERROR] [USB]
libusb_session_impl::libusb_event_handler_task: LIBUSB_ERROR_CODE -1" that
I get when specifying num_recv_frames, what could I do? Should I try a
different driver? Has anyone already experienced that error?

Thanks.
_______________________________________________
USRP-users mailing list
USRP-users@lists.ettus.com
http://lists.ettus.com/mailman/listinfo/usrp-users_lists.ettus.com