We are running OSPF and an EOIP tunnel. Eventually MPLS/VPLS. at this point, this isn't really a job for Mikrotik is it? The contractor is a multivendor shop, with a Cisco preference. We just stayed with the rb1100ahx2 because its what we use throughout the network, we knew it might be underpowered for this role.
I assume when we turn up IPV6 it will basically double the demand also with a second stack running? On Tue, May 9, 2017 at 7:50 AM, Dennis Burgess <[email protected]> wrote: > 1100ahx2 is not a good bgp router, go with a CCR 1036 at min, else > PowerRouter would be preferred. However, the CCRs can handle it as long as > you don’t load them with other stuffs. > > > > > > *Dennis Burgess** –** Network Solution Engineer – Consultant * > > MikroTik Certified Trainer/Consultant > <http://www.linktechs.net/productcart/pc/viewcontent.asp?idpage=5> – > MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE > > > > For Wireless Hardware/Routers visit www.linktechs.net > > Radio Frequency Coverages: www.towercoverage.com > > Office: 314-735-0270 <(314)%20735-0270> > > E-Mail: [email protected] > > > > *From:* Af [mailto:[email protected]] *On Behalf Of *Steve Jones > *Sent:* Monday, May 8, 2017 10:43 PM > *To:* [email protected] > *Subject:* [AFMUG] rb1100ahx2 bgp load > > > > We turned up BGP on one of our routers today, 2 peers, full routes, this > is just one upstream, we will be turning up bgp with another provider > shortly elsewhere on the network, I assume those tables will make their way > to this router. > > load averaged 4-12% prior to turning up BGP now its running 60-90, even > occasionally pegged > > > > is this a matter of tuning BGP and ROS packages, or is this just too much > for the router? this is only at 150mbps, as we increase capacity I feel we > have already scaled out of this router if its not a misconfiguration of > something on my end > > > > > > [image: Inline image 1] >