We are running OSPF and an EOIP tunnel. Eventually MPLS/VPLS. at this
point, this isn't really a job for Mikrotik is it? The contractor is a
multivendor shop, with a Cisco preference. We just stayed with the
rb1100ahx2 because its what we use throughout the network, we knew it might
be underpowered for this role.

I assume when we turn up IPV6 it will basically double the demand also with
a second stack running?

On Tue, May 9, 2017 at 7:50 AM, Dennis Burgess <[email protected]>
wrote:

> 1100ahx2 is not a good bgp router, go with a CCR 1036 at min, else
> PowerRouter would be preferred. However, the CCRs can handle it as long as
> you don’t load them with other stuffs.
>
>
>
>
>
> *Dennis Burgess** –** Network Solution Engineer – Consultant *
>
> MikroTik Certified Trainer/Consultant
> <http://www.linktechs.net/productcart/pc/viewcontent.asp?idpage=5> –
> MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE
>
>
>
> For Wireless Hardware/Routers visit www.linktechs.net
>
> Radio Frequency Coverages: www.towercoverage.com
>
> Office: 314-735-0270 <(314)%20735-0270>
>
> E-Mail: [email protected]
>
>
>
> *From:* Af [mailto:[email protected]] *On Behalf Of *Steve Jones
> *Sent:* Monday, May 8, 2017 10:43 PM
> *To:* [email protected]
> *Subject:* [AFMUG] rb1100ahx2 bgp load
>
>
>
> We turned up BGP on one of our routers today, 2 peers, full routes, this
> is just one upstream, we will be turning up bgp with another provider
> shortly elsewhere on the network, I assume those tables will make their way
> to this router.
>
> load averaged 4-12% prior to turning up BGP now its running 60-90, even
> occasionally pegged
>
>
>
> is this a matter of tuning BGP and ROS packages, or is this just too much
> for the router? this is only at 150mbps, as we increase capacity I feel we
> have already scaled out of this router if its not a misconfiguration of
> something on my end
>
>
>
>
>
> [image: Inline image 1]
>

Reply via email to