Yep.. ☺

Dennis Burgess – Network Solution Engineer – Consultant
MikroTik Certified 
Trainer/Consultant<http://www.linktechs.net/productcart/pc/viewcontent.asp?idpage=5>
 – MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE

For Wireless Hardware/Routers visit www.linktechs.net<http://www.linktechs.net/>
Radio Frequency Coverages: www.towercoverage.com<http://www.towercoverage.com/>
Office: 314-735-0270
E-Mail: [email protected]<mailto:[email protected]>

From: Af [mailto:[email protected]] On Behalf Of Mathew Howard
Sent: Tuesday, May 9, 2017 10:06 AM
To: af <[email protected]>
Subject: Re: [AFMUG] rb1100ahx2 bgp load

Mikrotik will do the job fine, you just need a bigger Mikrotik... x86 based, 
preferably.

On Tue, May 9, 2017 at 10:00 AM, Steve Jones 
<[email protected]<mailto:[email protected]>> wrote:
We are running OSPF and an EOIP tunnel. Eventually MPLS/VPLS. at this point, 
this isn't really a job for Mikrotik is it? The contractor is a multivendor 
shop, with a Cisco preference. We just stayed with the rb1100ahx2 because its 
what we use throughout the network, we knew it might be underpowered for this 
role.

I assume when we turn up IPV6 it will basically double the demand also with a 
second stack running?

On Tue, May 9, 2017 at 7:50 AM, Dennis Burgess 
<[email protected]<mailto:[email protected]>> wrote:
1100ahx2 is not a good bgp router, go with a CCR 1036 at min, else PowerRouter 
would be preferred. However, the CCRs can handle it as long as you don’t load 
them with other stuffs.


Dennis Burgess – Network Solution Engineer – Consultant
MikroTik Certified 
Trainer/Consultant<http://www.linktechs.net/productcart/pc/viewcontent.asp?idpage=5>
 – MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE

For Wireless Hardware/Routers visit www.linktechs.net<http://www.linktechs.net/>
Radio Frequency Coverages: www.towercoverage.com<http://www.towercoverage.com/>
Office: 314-735-0270<tel:(314)%20735-0270>
E-Mail: [email protected]<mailto:[email protected]>

From: Af [mailto:[email protected]<mailto:[email protected]>] On Behalf 
Of Steve Jones
Sent: Monday, May 8, 2017 10:43 PM
To: [email protected]<mailto:[email protected]>
Subject: [AFMUG] rb1100ahx2 bgp load

We turned up BGP on one of our routers today, 2 peers, full routes, this is 
just one upstream, we will be turning up bgp with another provider shortly 
elsewhere on the network, I assume those tables will make their way to this 
router.
load averaged 4-12% prior to turning up BGP now its running 60-90, even 
occasionally pegged

is this a matter of tuning BGP and ROS packages, or is this just too much for 
the router? this is only at 150mbps, as we increase capacity I feel we have 
already scaled out of this router if its not a misconfiguration of something on 
my end


[Inline image 1]