Yep.. ☺
Dennis Burgess – Network Solution Engineer – Consultant MikroTik Certified Trainer/Consultant<http://www.linktechs.net/productcart/pc/viewcontent.asp?idpage=5> – MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE For Wireless Hardware/Routers visit www.linktechs.net<http://www.linktechs.net/> Radio Frequency Coverages: www.towercoverage.com<http://www.towercoverage.com/> Office: 314-735-0270 E-Mail: [email protected]<mailto:[email protected]> From: Af [mailto:[email protected]] On Behalf Of Mathew Howard Sent: Tuesday, May 9, 2017 10:06 AM To: af <[email protected]> Subject: Re: [AFMUG] rb1100ahx2 bgp load Mikrotik will do the job fine, you just need a bigger Mikrotik... x86 based, preferably. On Tue, May 9, 2017 at 10:00 AM, Steve Jones <[email protected]<mailto:[email protected]>> wrote: We are running OSPF and an EOIP tunnel. Eventually MPLS/VPLS. at this point, this isn't really a job for Mikrotik is it? The contractor is a multivendor shop, with a Cisco preference. We just stayed with the rb1100ahx2 because its what we use throughout the network, we knew it might be underpowered for this role. I assume when we turn up IPV6 it will basically double the demand also with a second stack running? On Tue, May 9, 2017 at 7:50 AM, Dennis Burgess <[email protected]<mailto:[email protected]>> wrote: 1100ahx2 is not a good bgp router, go with a CCR 1036 at min, else PowerRouter would be preferred. However, the CCRs can handle it as long as you don’t load them with other stuffs. Dennis Burgess – Network Solution Engineer – Consultant MikroTik Certified Trainer/Consultant<http://www.linktechs.net/productcart/pc/viewcontent.asp?idpage=5> – MTCNA, MTCRE, MTCWE, MTCTCE, MTCINE For Wireless Hardware/Routers visit www.linktechs.net<http://www.linktechs.net/> Radio Frequency Coverages: www.towercoverage.com<http://www.towercoverage.com/> Office: 314-735-0270<tel:(314)%20735-0270> E-Mail: [email protected]<mailto:[email protected]> From: Af [mailto:[email protected]<mailto:[email protected]>] On Behalf Of Steve Jones Sent: Monday, May 8, 2017 10:43 PM To: [email protected]<mailto:[email protected]> Subject: [AFMUG] rb1100ahx2 bgp load We turned up BGP on one of our routers today, 2 peers, full routes, this is just one upstream, we will be turning up bgp with another provider shortly elsewhere on the network, I assume those tables will make their way to this router. load averaged 4-12% prior to turning up BGP now its running 60-90, even occasionally pegged is this a matter of tuning BGP and ROS packages, or is this just too much for the router? this is only at 150mbps, as we increase capacity I feel we have already scaled out of this router if its not a misconfiguration of something on my end [Inline image 1]
