On 09/15/2011 12:29 PM, Jon Elson wrote: > Mark Wendt wrote: >> I have one of those CNC4PC/Keling pendants. The e-stop works fine, >> but I've never been able to get the enable button to work. > That's because the white button is wired from the factory as Normally > CLOSED! > So, when you push it, it disconnects the wiper from the axis selector > knob. BUT, > the button is a SPDT switch, so you can move the wire inside to make > it a NO contact. > Otherwise, you could rig a memory element to the HAL code so that it > remembers the > last axis it saw, but only activates the jog function when there is no > axis contact selected. > Then it would work with the stock wiring of the pendant. I chose to > move the wire > inside. > > Jon > Jon,
Thanks. I'll give that a whirl. Mark ------------------------------------------------------------------------------ Doing More with Less: The Next Generation Virtual Desktop What are the key obstacles that have prevented many mid-market businesses from deploying virtual desktops? How do next-generation virtual desktops provide companies an easier-to-deploy, easier-to-manage and more affordable virtual desktop model.http://www.accelacomm.com/jaw/sfnl/114/51426474/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users