On Tue, 14 Jun 2011 11:03:49, "David Boyes" <dbo...@sinenomine.net> wrote:
> Problem is still going to be dealing with pages written during the first > few seconds after an IPL by CP itself. Hi David - one further comment - although it is indeed typical to see some CP owned pages written immediately after the system IPL, it's really not safe to make the assumption that that is the only time it will happen, In particular, the ISFC and Virtual Free Storage spaces are pageable, and page reference activity, and therefore paging behavior, for them can be driven at times other than system IPL. Bill Holder, Senior Software Engineer IBM z/VM Development, Memory Management, Endicott, NY Phone: 607-429-3640 IBM TieLine: 620-3640 ---------------------------------------------------------------------- For LINUX-390 subscribe / signoff / archive access instructions, send email to lists...@vm.marist.edu with the message: INFO LINUX-390 or visit http://www.marist.edu/htbin/wlvindex?LINUX-390 ---------------------------------------------------------------------- For more information on Linux on System z, visit http://wiki.linuxvm.org/