Am 08.01.2017 um 17:05 schrieb Colin Law: > > It is surely undeniable that this is a design flaw in the chip. Much > more sensible would have been to make it default to full scale (or > full negative scale), then it would have been much easier to program > around. > Full scale values mean there is a temperature above or below the temperature which can be sampled. Not just a single spot in the middle.
What's really missing is a distinct POR flag as the DS2408 has it. >> ... >> This has all been taken care for already, OWFS repeats a >> .../temperature triggered conversion for the case 85°C is the result. >> When you still have stray 85°C readings, it means your power failures >> are so serious you should check your hardware setup. > > Is that still the case? I thought there was some discussion here > recently about whether that code is in fact desirable and whether it > should be removed. Perhaps I misunderstood the conversation. > It's still in there, as Stefano found the real bug causing problems with .../latesttemp. Kind regards Jan ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, SlashDot.org! http://sdm.link/slashdot _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers