Re: [WiX-users] Burn does not show close application warning during uninstall

2015-05-26 Thread Sergey YUKHNO
@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wix-users -- Best regards, Sergey Yukhno Visutech System Ltd. tel.: +375 17 211 02 84 fax: +375 17 200 42 48 38 Nemiga St., Minsk, 220004 Republic of Belarus www.visutechsystem.by

[WiX-users] Visual studio 2008 and wix 3.9

2015-02-17 Thread Sergey Yukhno
Hello, Wix 3.9 doesn't support Visual Studio 2008 anymore? -- Best regards, Sergey Yukhno Visutech System Ltd. tel.: +375 17 211 02 84 fax: +375 17 200 42 48 38 Nemiga St., Minsk, 220004 Republic of Belarus www.visutechsystem.by

[WiX-users] Failed to write message type to pipe.

2014-12-19 Thread Sergey Yukhno
message to pipe. [18D0:13D0][2014-12-19T17:56:29]e000: Error 0x800700e8: Failed to send message to per-machine process. Depe -- Best regards, Sergey Yukhno Visutech System Ltd. tel.: +375 17 211 02 84 fax: +375 17 200 42 48 38 Nemiga St., Minsk, 220004 Republic of Belarus www.visutechsystem.by

[WiX-users] Minor upgrades if EnableFeatureSelection in bootstrapper.

2014-12-11 Thread Sergey Yukhno
). It is bug of bootstrapper engine? -- Best regards, Sergey Yukhno -- Download BIRT iHub F-Type - The Free Enterprise-Grade BIRT Server from Actuate! Instantly Supercharge Your Business Reports and Dashboards with Interactivity

[WiX-users] Msi features control from own burn application.

2013-12-23 Thread Sergey Yukhno
if features must be absent. Feature added successfully (property ADDLOCAL added), but removing isn't work. The best regards, Sergey Yukhno. -- Rapidly troubleshoot problems before they affect your business. Most

Re: [WiX-users] [WIX]: How to add ListView control using themes

2013-12-03 Thread Sergey Yukhno
Use not ListView ..., use Listview ... 11/28/2013 12:06, dileep s пишет: Hi All, How to add ListView control in themes file? I have create ListView control in HyperlinkTheme.xml Page Name=Install ListView Name=ListViewbox X=11 Y=50 Height=100 Width=100 Visible= yes TabStop=yes

[WiX-users] Disable control by condition in burn installer interface.

2013-10-07 Thread Sergey Yukhno
Hello, all. I'd like to disable some controls by burn's condition, VersionNT64 for example. It is possible without writing own bootstrapper application? The single way, that I see - is RegistrySearch element, but it improper for my case. Thanks, Sergey

[WiX-users] Error at creating user.

2013-04-11 Thread Sergey Yukhno
Impersonated custom action server. Action ended 9:38:38: ConfigureUsers. Return value 3. Thanks for your help, Sergey -- Precog is a next-generation analytics platform capable of advanced analytics on semi-structured data

[WiX-users] Can't install Wix 3.8 on Windows XP

2013-04-11 Thread Sergey Yukhno
Hello. Can't install Wix 3.8 on Windows XP. Wix38.exe is not valid Win32 application. Best regards, Sergey Yukhno. -- Precog is a next-generation analytics platform capable of advanced analytics on semi-structured data

Re: [WiX-users] Error at creating user.

2013-04-11 Thread Sergey Yukhno
using? On Thu, Apr 11, 2013 at 2:10 AM, Sergey Yukhno sergey.yuk...@visutechsystem.by wrote: Hello. Error at creating user on Windows XP with error dialog ...Setup wizard ended prematurely. Wix version 3.8. Directory Id=TARGETDIR Name=SourceDir Directory Id

Re: [WiX-users] Can't install Wix 3.8 on Windows XP

2013-04-11 Thread Sergey Yukhno
v3.8.309.0 and early. On 4/11/2013 17:18, Bruce Cran wrote: On 11/04/2013 14:23, Sergey Yukhno wrote: Can't install Wix 3.8 on Windows XP. Wix38.exe is not valid Win32 application. That looks like a problem with the VS 2012 settings. I thought we'd fixed them all - what build are you trying

[WiX-users] per-user install

2012-04-19 Thread Sergey
property. Its value is '3956'. *MSI (c) (74:48) [15:22:19:166]: PROPERTY CHANGE: Modifying ALLUSERS property. Its current value is '{}'. Its new value: '1'.* Why msiexec changes value of ALLUSERS to 1? How to find reason of it? -- Sergey

[WiX-users] VC2005 redistributables in per-user msi installation

2012-04-18 Thread Sergey
Property Id=ALLUSERS Value={} / /Fragment Target for VC redistributables is Windows folder. Regular user can not write to that folder. Is it possible to install VC2005 redistributables in per-user mode? What target folder must I use for them? -- Sergey

Re: [WiX-users] Burn: forceReboot and UI

2012-04-02 Thread Sergey Yukhno
Ok, the bug has been opened. On 3/30/2012 18:44, Rob Mensching wrote: Actually, this is a bug. The wixstdba should go straight back to progress after a force reboot and it obviously is not. Can you open the bug? On Thu, Mar 29, 2012 at 12:55 AM, Sergey Yukhno sergey.yuk...@visutechsystem.by

[WiX-users] Burn: forceReboot and UI

2012-03-29 Thread Sergey Yukhno
InstallCommand=/quiet /norestart Compressed=no InstallCondition=(NOT DotNetFramework40FullInstallRegValue=1) AND Feature1 ExitCode Behavior=forceReboot / /ExePackage Thanks for your help, Sergey -- This SF email is sponsosred

Re: [WiX-users] msp patch does not update one of files

2012-02-08 Thread Sergey
Engineer – ESA Jack Henry Associates, Inc.® Shawnee Mission, KS 66227 Office: 913-341-3434 x791011 jocoo...@jackhenry.com www.jackhenry.com -Original Message- From: Sergey [mailto:sh0...@gmail.com] Sent: Tuesday, February 07, 2012 3:13 AM To: General discussion for Windows

Re: [WiX-users] msp patch does not update one of files

2012-02-07 Thread Sergey
of the reason verbose logging every time during developmenttesting is so important ... to help with the forensics of what's happening. Blair -Original Message- From: Sergey [mailto:sh0...@gmail.com] Sent: Tuesday, January 31, 2012 10:40 PM To: General discussion for Windows

Re: [WiX-users] msp patch does not update one of files

2012-01-31 Thread Sergey
This behaviour is not stable. When I removed everything and repeated test again - file patched. This makes me frightened that on some clients' machines patch will work ok, but on some will fail. It is the worst variant, when I can not reproduce bug on my PC. 30.01.2012 21:46, Wilson, Phil

Re: [WiX-users] msp patch does not update one of files

2012-01-28 Thread Sergey
. 17:06 пользователь Gary Gocek g...@gocek.org написал: What kind of file is it (DLL, EXE, TXT, CONFIG, etc.)? If it's an unversioned file, try setting the key file to a versioned file, and use that ID as CompanionFile for the unversioned file. Gary -Original Message- From: Sergey

[WiX-users] msp patch does not update one of files

2012-01-27 Thread Sergey
Hello, I've created msp patch for my product. It must convert 3.1.4 version to 3.1.5 After I install it, it updates all needed files, changed in 3.1.5, except one file. This file is key file of component, containing only this file. How can I explore why it is happening? When I open msp file in

[WiX-users] major update which must uninstall previous installations with support of selection per user/per machine

2011-12-06 Thread Sergey
Hello, I have WIX project for product, which needs updates periodically. Also I block downgrade installations. There is a dialog in WIX, which allows to select between per user/per machine installation. Uninstall previous installations is handled using Upgrade table: Upgrade

[WiX-users] delivering only changed files in update

2011-11-11 Thread Sergey
Hello, I have WIX installation with a lot of huge files. Each time, when files are changing I prepare major upgrade (same upgrade code, new product code) with all the files. Now I also need to prepare msi, which would contain only changed files. So that user could download this update, install

Re: [WiX-users] UninstallShortcut

2011-06-10 Thread Sergey
-Original Message- From: Sergey [mailto:sh0...@gmail.com] Sent: 07 June 2011 11:23 To: General discussion for Windows Installer XML toolset. Subject: Re: [WiX-users] UninstallShortcut This tutorial is for per-user install. It contains this line of code: RegistryKey Root=HKCU But i

[WiX-users] UninstallShortcut

2011-06-07 Thread Sergey
Hello, I have installer, which allows to select between per-user install (ALLUSERS=1) and per-machine installation (ALLUSERS=). I create uninstall shortcut, using this WIX code: Component Id=Shortcuts Directory=WindowsFolder Guid=... RegistryValue Root=HKMU

Re: [WiX-users] UninstallShortcut

2011-06-07 Thread Sergey
I mistyped, in firs sentence. Correct version: I have installer, which allows to select between per-user install (ALLUSERS=) and per-machine installation (ALLUSERS=1). 07.06.2011 13:26, Sergey пишет: Hello, I have installer, which allows to select between per-user install (ALLUSERS=1

Re: [WiX-users] UninstallShortcut

2011-06-07 Thread Sergey
-an-uninstall-short cut-and-pass-all-the may help. -Original Message- From: Sergey [mailto:sh0...@gmail.com] Sent: 07 June 2011 10:31 To: General discussion for Windows Installer XML toolset. Subject: Re: [WiX-users] UninstallShortcut I mistyped, in firs sentence. Correct version

Re: [WiX-users] size of installation in Add\Remove programs applet

2011-05-25 Thread Sergey
How to write this custom action, which sum filesize values for all features, marked for installation? What language can i use for it? How to find out, if feature marked for installation? filesize for each feature i can hard write into code (it is known at design time). 25.05.2011 9:15, Blair

[WiX-users] size of installation in Add\Remove programs applet

2011-05-24 Thread Sergey
Hello, I have installation with a lot of features. CustomizeDlg allows to select what features to install. If user changes set of installed features, total size of installed files changes. In add\Remove programs applet size of program is displayed incorrectly. I found in google that i can use

[WiX-users] size of installation in Add\Remove programs applet

2011-05-24 Thread Sergey
Hello, I have installation with a lot of features. CustomizeDlg allows to select what features to install. If user changes set of installed features, total size of installed files changes. In add\Remove programs applet size of program is displayed incorrectly. I found in google that i can use

[WiX-users] features selection in CustomizeDlg

2011-04-22 Thread Sergey
Hello, I'm using CustomizeDlg in my progect for features selection. There are 3 levels of features. First-level feature contains features of second level. And each feature at second level contains subfeatures of third level. I launch installation, go to customize dialog, select popup menu of

[WiX-users] FormatSize attribute of text control

2011-03-31 Thread Sergey
Hi, I added this element to my CustomizeDlg: Control Id=PrimaryVolumeSpaceRequiredText Type=Text X=220 Y=58 Width=128 Height=20 Text=PrimaryVolumeSpaceRequired] FormatSize=yes / FormatSize works - i have a text in form 7533MB. But i need to have thousand separator in this number: 7,533MB. Is

[WiX-users] replace drop-down menu in customize dialog with checkbox

2011-03-18 Thread Sergey
Hi, i'm using Wix3, CustomizeDlg from wixui_common (attached to this email) When i launch my msi, on the left from feature name i have small icon with down arrow. If click on it, popup menu appears, with these items: - Will be installed on local hard drive - Entire feature will be installed

[WiX-users] Setup can't install drivers via DIFXApp.

2011-02-24 Thread Sergey Yukhno
Hi, Setup can't install driver via DIFXApp and installation process stopped with error. How to just show error message and continue. Difxapp element doesn't have necessary option. Sergey Yukhno. -- Free Software

Re: [WiX-users] Setup asks for rebooting after change/repair options.

2011-02-24 Thread Sergey Yukhno
. They are not likely to be the cause of the reboot. The log file will probably point out some other files. On Wed, Feb 23, 2011 at 11:53 PM, Sergey Yukhno sergey.yuk...@visutechsystem.by wrote: After change/repair options setups asks for rebooting. In setup log I found records that msi can't delete some

[WiX-users] Setup asks for rebooting after change/repair options.

2011-02-23 Thread Sergey Yukhno
After change/repair options setups asks for rebooting. In setup log I found records that msi can't delete some *.rbf files in directory setup.msi. What problem is? -- Free Software Download: Index, Search Analyze Logs

[WiX-users] huge product msi deployment via Active Directory

2011-02-17 Thread Sergey
Hi, I need to prepare msi installer, so that it could be installed via Active Directory on multiple computers in silent mode. Total size of files, i must redistribute is about 100Gb, so it would be significant optimization, not to pack into cab (or at least pack without compression) ant not

[WiX-users] how to uninstall product without UpgradeCode

2010-12-14 Thread Sergey
Hi, I need to prepare major update for msi product, which does not contain UpgradeCode. Is it possible to somehow uninstall previous product on RemoveExistingProducts, if i know its productCode? -- Sergey

Re: [WiX-users] how to uninstall product without UpgradeCode

2010-12-14 Thread Sergey
in Scotland No. SC151456 Registered Office - Helix Building, West Of Scotland Science Park, Glasgow G20 0SP Email Disclaimer -Original Message- From: Sergey [mailto:sh0...@gmail.com] Sent: 14 December 2010 10:43 To: wix-users@lists.sourceforge.net Subject: [WiX-users] how to uninstall

Re: [WiX-users] how to uninstall product without UpgradeCode

2010-12-14 Thread Sergey
** Integrated Environmental Solutions Limited. Registered in Scotland No. SC151456 Registered Office - Helix Building, West Of Scotland Science Park, Glasgow G20 0SP Email Disclaimer -Original Message- From: Sergey [mailto:sh0...@gmail.com] Sent: 14 December 2010 10:43 To: wix

Re: [WiX-users] Problem with update ComboBox control

2010-02-22 Thread Sergey Marudenko
the whole dialog and showing that after the CA is executed. On the second dialog, when the CA executed again, it must show the first dialog again. I hope you get what I mean :) Best regards, Sebastian Brand http://blog.sebastianbrand.com -Original Message- From: Sergey Marudenko

Re: [WiX-users] Problem with update ComboBox control

2010-02-21 Thread Sergey Marudenko
Hello Everybody. I got the same problem right now. But unfortunately I didn't see have you found working solution or not. Please help if you can! Thanks! -- View this message in context: http://old.nabble.com/Problem-with-update-%22ComboBox%22-control-tp20125554p27654837.html Sent from the

[WiX-users] do not executing custom actions on uninstall

2009-09-30 Thread Polazhenko Sergey
=check HideTarget=no / CustomAction Id=RegDocSource BinaryKey=ServerCA DllEntry=RegDocumentSource Execute=immediate Return=check HideTarget=no / __ WBR, Polazhenko Sergey -- Come build with us

Re: [WiX-users] do not executing custom actions on uninstall

2009-09-30 Thread Polazhenko Sergey
The target OS is Windows 2003 Server. __ WBR, Polazhenko Sergey -Original Message- From: Blair [mailto:os...@live.com] Sent: Wednesday, September 30, 2009 7:52 PM To: 'General discussion for Windows Installer XML toolset.' Subject: Re: [WiX-users] do

[WiX-users] Disallow empty installation

2009-09-07 Thread Polazhenko Sergey
Hello, Wix Users. I'm using WixUI_FeatureTree.wxs to select components during install. Installer allows installation even no feature was selected. How can I disable 'Next' button in case no feature was selected. Thanks. __ WBR, Polazhenko Sergey

[WiX-users] run BAT files hiddenly

2009-09-07 Thread Polazhenko Sergey
parameter. But I wonder is there more simple way to resolve this issue. Thanks. __ WBR, Polazhenko Sergey -- Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day trial

[WiX-users] run more than one application after install

2009-09-07 Thread Polazhenko Sergey
Sergey -- Let Crystal Reports handle the reporting - Free Crystal Reports 2008 30-Day trial. Simplify your report design, integration and deployment - and focus on what you do best, core application coding. Discover what's

[WiX-users] Per-user install, no per-user uninstall?

2009-08-08 Thread Sergey Vlasov
Hello, I'm developing a strictly per-user installer using WiX. It writes files only to user's documents directory and creates registry keys only in HKCU. Installation and uninstallation work fine except one special case. When access to user's documents directory is restricted only to the

Re: [WiX-users] client setup

2009-07-21 Thread Polazhenko Sergey
create two installation packages for 32 and 64 bit operation systems. Though it is much more convenient to have one installer in a Active Directory GPO. Thanks. _ WBR, Polazhenko Sergey -Original Message- From: Sascha Beaumont [mailto:sascha.beaum...@gmail.com

[WiX-users] client setup

2009-07-20 Thread Polazhenko Sergey
setting from the property, stored inside that MSI file. Thanks! __ WBR, Polazhenko Sergey -- Enter the BlackBerry Developer Challenge This is your chance to win up to $100,000 in prizes! For a limited time, vendors

[WiX-users] client setup

2009-07-20 Thread Polazhenko Sergey
setting from the property, stored inside that MSI file. Thanks! __ WBR, Polazhenko Sergey -- Enter the BlackBerry Developer Challenge This is your chance to win up to $100,000 in prizes! For a limited time, vendors

Re: [WiX-users] Control.Default and Edit control

2009-05-11 Thread Sergey Abakumoff
Any ideas about my question? Maybe the description is unclear, so let me re-formulate.. The default behavior of the PushButton control(if user presses Enter key, then the control is invoked) does not work if there is the Edit control in the dialog and this control is activated(i.e. user typed

Re: [WiX-users] Publish several events with condition.

2009-05-07 Thread Sergey Abakumoff
Thanks you very much, it worked like a charm. Richard-45 wrote: Windows Installer doesn't realize that the property value has changed inside your custom action. The workaround is to add a control event after the DoAction event that sets the property to itself, i.e. Publish

[WiX-users] Control.Default and Edit control

2009-05-07 Thread Sergey Abakumoff
There are the following elements in one of the dialogs of my installer: Edit controls, i.e.: Control Id=SerialEdit Type=Edit X=15 Y=150 Width=220 Height=16 Property=SERIALNUMBER Text={20} / PushButton control that has Default attribute is set to yes: Control Id=License Default=yes

[WiX-users] Publish several events with condition.

2009-05-06 Thread Sergey Abakumoff
What I am trying to accomplish: In one of the dialogs of my installer, I call the custom action of type 6(VBScript file stored in a Binary table stream) when user clicks on the button: Control Id=License Type=PushButton Publish Event=DoAction Value=LicenseProductVbs /

[WiX-users] Setting the progress text of custom action dynamically

2008-11-03 Thread Sergey Abakumoff
Howdy, In my installer I use WixVsExtension to call devenv.exe /installvstemplates for VS.NET 2005/2008, here is the part of code: InstallExecuteSequence Custom Action=VS90InstallVSTemplates Before=InstallFinalizeVS90DEVENV/Custom Custom Action=VS2005InstallVSTemplates

Re: [WiX-users] Using single Dialog to change various paths.

2008-10-25 Thread Sergey Abakumoff
Yep, it was my obvious fault. Publish Property=_BrowseProperty Value=INSTALLDIR1/Publish should be used. Thank you and sorry for very long discussion around the very simple thing. Bob Arnson-6 wrote: Sergey Abakumoff wrote: Publish Property=_BrowseProperty Value=INSTALLDIR

Re: [WiX-users] Skip dialog during uninstall

2008-10-24 Thread Sergey Abakumoff
Howdy gang, First of all, I have solved the original problem that I described in the first post: In my installer I should show licensing dialog at the end of installation. If the product is removed, the licensing dialog should not be shown though and user exit dialog should be shown instead. I

Re: [WiX-users] Using single Dialog to change various paths.

2008-10-24 Thread Sergey Abakumoff
Unfortunately, this doesn't help..Does anyone have any other ideas? TIA Richard-45 wrote: In article [EMAIL PROTECTED], Sergey Abakumoff [EMAIL PROTECTED] writes: Publish Property=_BrowseProperty Value=[INSTALLDIR] / Publish Property=_BrowseProperty Value

Re: [WiX-users] Using single Dialog to change various paths.

2008-10-24 Thread Sergey Abakumoff
BrowseDlg always shows SAMPLESDIR folder, it doesn't matter that button was clicked - ProgramFilesBrowse or SamplesBrowse. So it seems that _BrowseProperty always set to SAMPLESDIR and setting it to INSTALLDIR in the custom action doesn't have any effect. Bob Arnson-6 wrote: Sergey

Re: [WiX-users] Using single Dialog to change various paths.

2008-10-24 Thread Sergey Abakumoff
and similar one for SamplesFolder... Richard-45 wrote: In article [EMAIL PROTECTED], Sergey Abakumoff [EMAIL PROTECTED] writes: BrowseDlg always shows SAMPLESDIR folder, it doesn't matter that button was clicked - ProgramFilesBrowse or SamplesBrowse. So it seems that _BrowseProperty

Re: [WiX-users] Using single Dialog to change various paths.

2008-10-24 Thread Sergey Abakumoff
Richard, In the first post I mentioned that I use custom action. It was suggested in the reply that set property event should be used and I started to use that:) However, it didn't solve the problem as I mentioned. Richard-45 wrote: In article [EMAIL PROTECTED], Sergey Abakumoff

Re: [WiX-users] Skip dialog during uninstall

2008-10-23 Thread Sergey Abakumoff
Thanks for the prompt reply. We agreed to move licensing dialog to before the install, namely exactly after Welcome dialog that is shown after CostFinalize. However, I faced another problem that I hope you can help me to solve. In our licensing dialog users enter their licensing info and we

Re: [WiX-users] Skip dialog during uninstall

2008-10-23 Thread Sergey Abakumoff
Sorry, I can't find any real example of such an action. Could you please explain how to do that? Brian Rogers-3 wrote: You can embed the EXE as a binary resource in the MSI. Then you can write a custom action which extracts it to a temporary folder and runs it. -- View this message in

Re: [WiX-users] Skip dialog during uninstall

2008-10-23 Thread Sergey Abakumoff
Thanks you all, guys. I will try solution 2 tomorrow and let you know whether it helps... Bob Arnson-6 wrote: Sergey Abakumoff wrote: An executable that modifies the system can't run during the UI sequence. There are a couple of choices: 1. Don't use a Windows Installer dialog to collect

[WiX-users] Skip dialog during uninstall

2008-10-21 Thread Sergey Abakumoff
Howdy, In my installer I should show licensing dialog at the end of installation. If the product is removed, the licensing dialog should not be shown though and user exit dialog should be shown instead. I try to use conditions like below: InstallUISequence Show Dialog=LicensingDlg

[WiX-users] Detect the version of already installed product.

2008-10-17 Thread Sergey Abakumoff
Howdy gang, In my installer I need to notify user if the previous version of product is installed and show the version number. I was hoping that I can find the already installed version number in PATCHFOUND property I use in UpgradeVersion stuff: Upgrade

[WiX-users] Weird dialog behaviour

2008-10-04 Thread Sergey Abakumoff
I use the following dialog in my installer: Dialog Id=CustomizeDlg Width=370 Height=270 Title=[ProductName] [Setup] NoMinimize=yes ?include Banners.wxi ? Control Id=Install Type=PushButton X=220 Y=250 Width=56 Height=17 Text=Install Publish Event=NewDialog

[WiX-users] Using single Dialog to change various paths.

2008-09-25 Thread Sergey Abakumoff
There are two paths that can be edited by user in my installer(The directory names are SAMPLESDIR and INSTALLDIR). I would like to use the same Browse Dialog to allow changing both of paths. First of all I defined new _BrowseProperty: Property Id=_BrowseProperty Value=SAMPLESDIR / Then, I defined

Re: [WiX-users] Using single Dialog to change various paths.

2008-09-25 Thread Sergey Abakumoff
Richard-45 wrote: Don't use DoAction to change the property, use a property setting control event. Even though I use property setting control event: Control Id=ProgramFilesBrowse Type=PushButton X=304 Y=70 Width=56 Height=17 Cancel=yes Text=Browse... Publish

[WiX-users] Edit text and button state.

2008-09-22 Thread Sergey Abakumoff
Hello, I am trying to implement the following feature: There are the edit text and push button text in the dialog. I want to have the button disabled if the text field is empty but once end-users starts entering the text, enable the button. if the text is edited and becomes empty, disable the

Re: [WiX-users] Enable/Disable button based on checkbox value??

2008-09-19 Thread Sergey Abakumoff
Okay, I changed the value of checkbox to 1 : CheckBoxValue=1 and now it works fine. However, I can't figure out what is the difference.. If anyone can explain, it would be great! -- View this message in context:

[WiX-users] Check whether VS.NET is installed.

2008-09-11 Thread Sergey Abakumoff
My setup package has to install certain components only if VS.NET 2005 SP1 is installed or VS.NET 2008 is installed. With Wix how can I check the presence of VS.NET versions? -- View this message in context: http://n2.nabble.com/Check-whether-VS.NET-is-installed.-tp1082028p1082028.html Sent

Re: [WiX-users] Check whether VS.NET is installed.

2008-09-11 Thread Sergey Abakumoff
Found the answer myself: * Define the following properties: Property Id=VSNET2005 RegistrySearch Id=VsNet2005 Root=HKLM Key=SOFTWARE\Microsoft\VisualStudio\8.0 Name=InstallDir Type=raw / /Property Property

[WiX-users] Install components to the existing folder.

2008-09-11 Thread Sergey Abakumoff
Hello, I try to install VS.NET templates as part of the setup package. To do that I first read the path to VS.NET: Property Id=VSNET2005 RegistrySearch Id=VsNet2005 Root=HKLM Key=SOFTWARE\Microsoft\VisualStudio\8.0 Name=InstallDir

[WiX-users] Wix, satellite assemblies and GAC.

2008-09-08 Thread Sergey Abakumoff
quoted text - On Fri, Sep 5, 2008 at 2:40 PM, Sergey Abakumoff [EMAIL PROTECTED]wrote: Thanks, it works like a charm! On Fri, Sep 5, 2008 at 2:21 PM, Rob Mensching [EMAIL PROTECTED]wrote: Maybe just give the two File elements different Name attribute values. -Original Message- From

Re: [WiX-users] Install satellite assemblies in GAC

2008-09-08 Thread Sergey Abakumoff
quoted text - On Fri, Sep 5, 2008 at 2:40 PM, Sergey Abakumoff [EMAIL PROTECTED]wrote: Thanks, it works like a charm! On Fri, Sep 5, 2008 at 2:21 PM, Rob Mensching [EMAIL PROTECTED]wrote: Maybe just give the two File elements different Name attribute values. -Original Message- From

[WiX-users] Install satellite assemblies in GAC, Part 2

2008-09-08 Thread Sergey Abakumoff
I tried to resolve the Wix linker error that appeared if I tried to install the multiple assemblies with the same name but the different cultures in the GAC - see the details in: http://sourceforge.net/mailarchive/message.php?msg_name=122b47a20809050040t60854b7as451da8d292543b80%40mail.gmail.com

Re: [WiX-users] Install satellite assemblies in GAC

2008-09-05 Thread Sergey Abakumoff
Thanks, it works like a charm! On Fri, Sep 5, 2008 at 2:21 PM, Rob Mensching [EMAIL PROTECTED]wrote: Maybe just give the two File elements different Name attribute values. -Original Message- From: [EMAIL PROTECTED] [mailto: [EMAIL PROTECTED] On Behalf Of Sergey Abakumoff Sent

[WiX-users] Check of _changing_ properties from UI Dialog.

2006-11-15 Thread Sergey Balobin
Hello, All! I`m writing an installation in WIX 1. During the installation I run a Custom-Action that doing something and make record in the registry. 2. I want the text in ExitDialog to be changed depends on the registry changes. I created a Custom-Action DLL function that checks the registry