Yuck!

Looking at your screenshot again - the VAC Control Panel window - you're
going to have all sorts of rate conversions running, your cables are using
44,100 as their sample rate.

I would use a sample rate of 48,000 or 8,000 and *not* have the cable
running internally at 44,100, essentially keep the same sample rate running
through the whole process to avoid rate conversions.

Converting 8,000 <=> 48,000 should be clean but converting 44,100 <=> 48,000
could be messy.

Simon Brown, HB9DRV
http://sdr-radio.com


> -----Original Message-----
> From: flexradio-boun...@flex-radio.biz [mailto:flexradio-boun...@flex-
> radio.biz] On Behalf Of Steven L Hess
> 
> Simon this is what I have
> Vac Settings PowerSDR settings
> <http://www.slhess.com/pictures/VACsetings.png>
> 