In that case Mike, the cplevel reported at ipl time wouldn't show the new
build date.
The lack of any maintenance in the RSU for HCPCPE would indicate the RSU
wasn't complete in that regard and it's time to open a PMR.

--
Mike Harding
z/VM System Support

mhard...@us.ibm.com
mike.b.hard...@kp.org
mikehard...@mindless.com
(925) 926-3179 (w)
(925) 323-2070 (c)
IM: VMBearDad (AIM),  mbhcpcvt (Y!)


The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU> wrote on 10/20/2010
02:10:34 PM:

> From: Mike Walter <mike.wal...@hewitt.com>
> To: IBMVM@LISTSERV.UARK.EDU
> Date: 10/20/2010 02:10 PM
> Subject: Re: RSU or PSU?
> Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
>
> George,
>
> One more thing... might you have moved the CF1, CF2, and or CF3 MDISK
> location (perhaps to enlarge them) and forgotten to re-run CPFMTXA to
> change the PARM disk allocations?  If so, that could be it... when CP is
> IPLed, it's going to look at the first PARM disk allocation.  At that
> point CP knows nothing about MDISKs defined in the directory, it's too
> soon in the IPL to have read in and processed the DRCT (object directory)

> cylinders.
>
> Mike Walter
> Aon Hewitt
> The opinions expressed herein are mine alone, not my employer's.
>
>

Reply via email to