I have sen mkh40 and the rest of that series,  plus schoeps ccm cardioids
and OMNIs, along with the DPA4006.
The Dpa has the individual factory measurenent trace, which makes it more
useful as reference.

On Sat, 4 Nov 2023, 13:48 jack reynolds, <jackreynolds...@gmail.com> wrote:

> Thanks Steven.
>
> Do you know the quoted EIN specs for the RMEs?
>
> It might be fun to run an EIN test to see how the RME gains affect the
> preamp noisefloor, but I'm not sure the RME will be much quieter than the
> F8. They are pretty state of the art.
>
> The Millenia Len mentioned is a different beast but it costs four times as
> much as an F8 just for the preamps, so you'd hope it sounded better!
>
> I think an on axis recording of a single Tetra capsule would be worth
> having though, with pink noise at a measured SPL with an on axis DPA4006
> to compare to, rather than upright.
>
> Unless you have any high end cardioids? I've got a Sennheiser 8040 that
> could work, just as a known reference.
>
> J
>