It would be usefull command like show spanning tree vlan 52 and 211

Am I receveing a output like: P2p Bound(PVST) *PVST_Inc





Because I am thinking if there are switches that speaking PVST+.

When I mix PVST+ and MSTP The PVST+ domain have to  either host root
switches for any vlan's or none.

Cisco don't support hosting PVST+ of any of the root bridges, therefore
all root bridges have to belong to MSTP domain.

The MSTP edge ports will emulate PVST+ packets based to instance
configuration.

Furthemore  I am thinking and the priority values for any vlans
override STP priority for any PVST+ vlans configured



That just my thought.







On Thu, Sep 5, 2013, at 05:57 PM, Marko Milivojevic wrote:

You're getting close! :-)



On Thu, Sep 5, 2013 at 5:56 AM, Mills, Derek
<[1][email protected]> wrote:

Does this have anything to do with VLAN211 being in MST instance 0 and
VLAN52 in MST instance 1?





-----Original Message-----

From: [2][email protected]
[mailto:[3][email protected]] On Behalf Of Marko
Milivojevic

Sent: Tuesday, September 03, 2013 3:15 PM

To: [email protected]

Cc: OSL Routing and Switching

Subject: Re: [OSL | CCIE_RS] WB3-Lab9-L2VPN Task



Again, this is not related to AToM :-)





On Tue, Sep 3, 2013 at 1:14 PM, <[email protected]> wrote:



> **



> The only thing I can think of problems connected to the STP with

> mismatching vlans in VLAN CONNECT MODE.

> If I am not mistake there are 2 kind of VC type:  port-mode or

> VLAN-mode for Ethernet L2VPNs.

> A PortMode  will replicate all Ethernet frames received, including
all

> tagged frames.

> Perhaps in port mode we have not the problem about mismatching vlan

>

> In VLAN-based mode  we will have xconnect statement will be under a

> sub-interface with own encapsulation and VLAN number specified.

> This mode will just forward the own VLAN frames through pseudowire.

>

> However I think to replicate this problem.

>

>

> On Tue, Sep 3, 2013, at 10:04 PM, Marko Milivojevic wrote:

>

> Sure, but that will open the network for the loops.

>

> Try to focus on what the problem is, not how to get rid of the
symptom

> :-)

>

> --

> Marko Milivojevic - CCIE #18427 (SP R&S) Senior CCIE Instructor /

> Managing Partner - IPexpert

>

>

> On Tue, Sep 3, 2013 at 1:02 PM, <[email protected]> wrote:

>

>

> **



> There are other solution for example vlan filter, also L2 protocol

> tunnel which erase local bpdu processing.

>

>

>

>

> On Tue, Sep 3, 2013, at 09:57 PM, [email protected] wrote:

>

> I am thinking we filtering bpdu to stop bpdu from blocking

> inconsistent vlan,bpdu filtering is acceptable for me.

>

> What did you think?

>

>

>

> On Tue, Sep 3, 2013, at 08:17 PM, Marko Milivojevic wrote:

>

> You're getting close.

>

>

> Respond to the list, please, as it may be interesting for the others

> to see, as well.

>

> --

> Marko Milivojevic - CCIE #18427 (SP R&S) Senior CCIE Instructor /

> Managing Partner - IPexpert

>

>

> On Tue, Sep 3, 2013 at 11:16 AM, <[email protected]> wrote:

>

>

> **



> In fact I did not think it is related to l2vpn, althhough I  do not
> know different vlan to VC however I am thinking is related config to
> port or mode spanning tree, I will check conifguration to end point
> port: if 802.1q to two side and native vlans, or model of stp EEE
> 802.1D and pvst+
>
>
> On Tue, Sep 3, 2013, at 07:32 PM, Marko Milivojevic wrote:
>
> That is all very correct, but that's not the cause of the error. You
> *can* have different VLAN IDs on two ends of the VC, but then you
need
> to make sure something else is done. Something that causes this
problem.
>
> Btw. it's not related to L2VPNs :-)
>
> --
> Marko Milivojevic - CCIE #18427 (SP R&S) Senior CCIE Instructor /
> Managing Partner - IPexpert
>
>
> On Tue, Sep 3, 2013 at 9:45 AM, <[email protected]> wrote:
>
> Point-to-Point L2 VPNs L2 connectivity to the attached, that make
> circuits of two separate sites connected across a packet network
> Furthemore It provide connectivity transparent without need L2
> connection acrosss SP core
>
>  In the speficic:
>
>  The VC identifiers at each end must match, so that the connection is
> uniquely  addressed and MTU settings for the interfaces would have
the
> same
>
>  In mpls the topmost label is the transport label for the  other
end's
> 1321P address and the second label identifies the remote AC
>
>  Your error usually mean you receveid bpdu tagged with vlan id that
> does't match vlan id where bpdu was receveid  In the meantime make
> sure native vlan is consistent on both ends of a  802.1Q trunk and
> your vtp switches setup  like VTP mode and domain names
>
>  I hope it help you.
>
>
>
>
>
>  On Tue, Sep 3, 2013, at 06:00 PM, Marko Milivojevic wrote:
>  > Without straight-out giving you an answer (tell me if you want
> that),  > let's  > try to understand the problem first…  >  > What do
> you think is causing this inconsistency?
>  >
>  > --
>  > Marko Milivojevic - CCIE #18427 (SP R&S)  > Senior CCIE Instructor
> / Managing Partner - IPexpert  >  >  > On Tue, Sep 3, 2013 at 8:36
AM,
> Saleh Batouq <[4][email protected]>  > wrote:
>  >
>  > > WB3-Lab9
>  > > --------
>  > > Task: L2VPN
>  > > ------
>  > >
>  > >
>  > > I am running this on GNS, I have the AToM properly configured
and
> > > functional.
>  > >
>  > > BUT I get Inconsistency messege on Cat1 & Cat3  > >  > > Any
> suggestion on over-riding this inconsistency?
>  > >
>  > >
>  > >
>  > >
>  > > The following are the outputs of show commands:
>  > >
>  > >
>  > >
>  > >
>  > > On R2
>  > > -----
>  > >
>  > > R2#sh mpls l2transport vc
>  > >
>  > > Local intf     Local circuit              Dest address    VC ID
>  Status
>  > > -------------  -------------------------- ---------------
> ----------  > > ----------
>  > > Fa0/0.211      Eth VLAN 211               70.18.115.5     25
> UP
>  > >
>  > >
>  > > On R5
>  > > ------
>  > >
>  > > R5#sh mpls l2transport vc
>  > >
>  > > Local intf     Local circuit              Dest address    VC ID
>  Status
>  > > -------------  -------------------------- ---------------
> ----------  > > ----------
>  > > Fa0/1.52       Eth VLAN 52                70.18.115.2     25
> UP
>  > >
>  > >
>  > >
>  > >
>  > >
>  > > BUT I get Inconsistency messege on Cat1 & Cat3  > >
> --------------------------------------------------
>  > >
>  > >
>  > > On Cat1
>  > > -------
>  > >
>  > > Cat1(config)# PVST+:Inconsistency timer expired. inconsistency 2
>  > >                  cleared for FastEthernet1/2
>  > >
>  > > *Mar  1 01:44:56.119: %SPANTREE-2-RECV_PVID_ERR: Received BPDU
> with  > > inconsistent peer vlan id 52 on FastEthernet1/2 VLAN211.
>  > > *Mar  1 01:44:56.119: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking  >
>
> FastEthernet1/2 on VLAN211. Inconsistent local vlan.
>  > >
>  > >
>  > >
>  > > Cat1#sh spanning-tree inconsistentports  > >
>  > > Name                 Interface            Inconsistency
>  > > -------------------- -------------------- ------------------
>  > > VLAN211              FastEthernet1/2      Port VLAN ID Mismatch
>  > >
>  > > Number of inconsistent ports (segments) in the system : 1  > >
>
> > On Cat3  > > -------  > >  > > [OK]  > > Cat3#  > > *Mar  1
> 01:44:49.487: %SPANTREE-2-RECV_PVID_ERR: Received BPDU with  > >
> inconsistent peer vlan id 211 on FastEthernet1/5 VLAN52.
>  > > *Mar  1 01:44:49.487: %SPANTREE-2-BLOCK_PVID_LOCAL: Blocking  >
>
> FastEthernet1/5 on VLAN52. Inconsistent local vlan.
>  > >
>  > >
>  > > Cat3#sh spanning-tree inconsistentports  > >
>  > > Name                 Interface            Inconsistency
>  > > -------------------- -------------------- ------------------
>  > > VLAN52               FastEthernet1/5      Port VLAN ID Mismatch
>  > >
>  > > Number of inconsistent ports (segments) in the system : 1  > >
>
> > Best Regards,  > >  > > Saleh Hassan Batouq  > >
> [5][email protected]  > >
> _______________________________________________
>  > > For more information regarding industry leading CCIE Lab
> training, please  > > visit [6]www.ipexpert.com  > >  > > Are you a
CCNP
> or CCIE and looking for a job? Check out  > >
> [7]www.PlatinumPlacement.com  > >  > >
> [8]http://onlinestudylist.com/mailman/listinfo/ccie_rs
>  > >
>  > _______________________________________________
>  > For more information regarding industry leading CCIE Lab training,
> please  > visit [9]www.ipexpert.com  >  > Are you a CCNP or CCIE and
> looking for a job? Check out  > [10]www.PlatinumPlacement.com  >  >
> [11]http://onlinestudylist.com/mailman/listinfo/ccie_rs
>
>
>  --
>  This message is intended for the individual(s) to whom it is
> addressed  and may contain information that is privileged or
confidential.
>  If you are not the addressee you must not read,use or disclose the
> contents of this email.
>  Whilst all reasonable care has been taken to avoid the transmission
> of  viruses, the recipient should carry out virus and other checks,
> as they consider appropriate.
>  Myself accepts no responsibility in this regard.
> _______________________________________________
>  For more information regarding industry leading CCIE Lab training,
> please visit [12]www.ipexpert.com
>
>  Are you a CCNP or CCIE and looking for a job? Check out
> [13]www.PlatinumPlacement.com
>
>  [14]http://onlinestudylist.com/mailman/listinfo/ccie_rs
>
>
>
>
> --
> This message is intended for the individual(s) to whom it is
addressed
> and may contain information that is privileged or confidential.
> If you are not the addressee you must not read,use or disclose the
> contents of this email.
> Whilst all reasonable care has been taken to avoid the transmission
of
> viruses, the recipient should carry out virus and other checks, as
> they consider appropriate.
> Myself accepts no responsibility in this regard.
>
>
>
>
>
>
> --
> This message is intended for the individual(s) to whom it is
addressed
> and may contain information that is privileged or confidential.
> If you are not the addressee you must not read,use or disclose the
> contents of this email.
> Whilst all reasonable care has been taken to avoid the transmission
of
> viruses, the recipient should carry out virus and other checks, as
> they consider appropriate.
> Myself accepts no responsibility in this regard.
>
>
>
>
> --
> This message is intended for the individual(s) to whom it is
addressed
> and may contain information that is privileged or confidential.
> If you are not the addressee you must not read,use or disclose the
> contents of this email.
> Whilst all reasonable care has been taken to avoid the transmission
of
> viruses, the recipient should carry out virus and other checks, as
> they consider appropriate.
> Myself accepts no responsibility in this regard.
>
>
>
>
>
>
> --
> This message is intended for the individual(s) to whom it is
addressed
> and may contain information that is privileged or confidential.
> If you are not the addressee you must not read,use or disclose the
> contents of this email.
> Whilst all reasonable care has been taken to avoid the transmission
of
> viruses, the recipient should carry out virus and other checks, as
> they consider appropriate.
> Myself accepts no responsibility in this regard.
>
>
>
_______________________________________________
For more information regarding industry leading CCIE Lab training,
please visit [15]www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out
[16]www.PlatinumPlacement.com

[17]http://onlinestudylist.com/mailman/listinfo/ccie_rs

-----------------------------------------------------------------------
-----------------------------------------------------------------------
-----------------------------------------------------------------------
-------------------------------------------------------------------
Anheuser-Busch InBev Email Disclaimer [18]www.ab-inbev.com




--
This message is intended for the individual(s) to whom it is addressed
and may contain information that is privileged or confidential.
If you are not the addressee you must not read,use or disclose the
contents of this email.
Whilst all reasonable care has been taken to avoid the transmission of
viruses, the recipient should carry out virus and other checks,
as they consider appropriate.
Myself accepts no responsibility in this regard.

References

1. mailto:[email protected]
2. mailto:[email protected]
3. mailto:[email protected]
4. mailto:[email protected]
5. mailto:[email protected]
6. http://www.ipexpert.com/
7. http://www.PlatinumPlacement.com/
8. http://onlinestudylist.com/mailman/listinfo/ccie_rs
9. http://www.ipexpert.com/
  10. http://www.PlatinumPlacement.com/
  11. http://onlinestudylist.com/mailman/listinfo/ccie_rs
  12. http://www.ipexpert.com/
  13. http://www.PlatinumPlacement.com/
  14. http://onlinestudylist.com/mailman/listinfo/ccie_rs
  15. http://www.ipexpert.com/
  16. http://www.PlatinumPlacement.com/
  17. http://onlinestudylist.com/mailman/listinfo/ccie_rs
  18. http://www.ab-inbev.com/
_______________________________________________
For more information regarding industry leading CCIE Lab training, please visit 
www.ipexpert.com

Are you a CCNP or CCIE and looking for a job? Check out 
www.PlatinumPlacement.com

http://onlinestudylist.com/mailman/listinfo/ccie_rs

Reply via email to